SpecDirectory

Daikin RX09BXVJUvsTCL H09SBH23BPC

Side-by-side heat pump comparison

Daikin RX09BXVJU

SEER2

20BTU/Wh

HSPF2

10BTU/Wh

Cooling Capacity

8900BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

TCL H09SBH23BPC

SEER2

23BTU/Wh

HSPF2

9.5BTU/Wh

Cooling Capacity

9000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

TCL H09SBH23BPC is 13% more efficient at 23.0 BTU/Wh versus 20.0 BTU/Wh for the Daikin RX09BXVJU. The TCL H09SBH23BPC is larger at 9000 BTU/hr versus 8900 BTU/hr. TCL H09SBH23BPC uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088).

Efficiency

SpecDaikinTCL
SEER2 (best combination)(BTU/Wh)2023
SEER2 (worst combination)(BTU/Wh)2023
HSPF2 (best combination)(BTU/Wh)109.5
HSPF2 (worst combination)(BTU/Wh)109.5
EER2 (best combination)(BTU/Wh)12.513
COP at 5 °F1.801.90

Capacity

SpecDaikinTCL
Cooling Capacity (max)(BTU/hr)89009000
Cooling Capacity (min)(BTU/hr)89009000
Heating at 47 °F(BTU/hr)1000010000
Heating at 17 °F(BTU/hr)62008000
Heating at 5 °F(BTU/hr)58007100

Configuration

SpecDaikinTCL
Product TypeHP - Mini or Multi SplitHP - Mini or Multi Split
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedNoYes
Connected CapabilityNoNo
SeriesDaikin OTERRABREEZEIN
Indoor-Unit Combinations Rated11

Refrigerant

SpecDaikinTCL
TypeR-410AR-454B
GWP RatingR-410A (GWP:2088)R-454B (GWP:470 | Lower GWP)

More comparisons