SpecDirectory

Daikin RXT12AVJU*vsROVSUN TC-12CHRH/DVO-D

Side-by-side heat pump comparison

Daikin RXT12AVJU*

SEER2

20BTU/Wh

HSPF2

10.2BTU/Wh

Cooling Capacity

10600BTU/hr

Cold Climate

Yes

Cold climate certified

ROVSUN TC-12CHRH/DVO-D

SEER2

19BTU/Wh

HSPF2

8.4BTU/Wh

Cooling Capacity

11000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Daikin RXT12AVJU* is 5% more efficient at 20.0 BTU/Wh versus 19.0 BTU/Wh for the ROVSUN TC-12CHRH/DVO-D. The ROVSUN TC-12CHRH/DVO-D is larger at 11000 BTU/hr versus 10600 BTU/hr. ROVSUN TC-12CHRH/DVO-D uses a lower-impact refrigerant: R-454B (GWP 470) versus R-32 (GWP 675).

Efficiency

SpecDaikinROVSUN
SEER2 (best combination)(BTU/Wh)2019
SEER2 (worst combination)(BTU/Wh)2019
HSPF2 (best combination)(BTU/Wh)10.28.4
HSPF2 (worst combination)(BTU/Wh)10.28.4
EER2 (best combination)(BTU/Wh)1211
COP at 5 °F1.801.80

Capacity

SpecDaikinROVSUN
Cooling Capacity (max)(BTU/hr)1060011000
Cooling Capacity (min)(BTU/hr)1060011000
Heating at 47 °F(BTU/hr)1350012000
Heating at 17 °F(BTU/hr)950010200
Heating at 5 °F(BTU/hr)135008800

Configuration

SpecDaikinROVSUN
Product TypeHP - Mini or Multi SplitHP - Mini or Multi Split
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesAURORACASSETTE-single
Indoor-Unit Combinations Rated11

Refrigerant

SpecDaikinROVSUN
TypeR-32R-454B
GWP RatingR-32 (GWP:675 | Lower GWP)R-454B (GWP:470 | Lower GWP)

More comparisons