SpecDirectory

DIRECT AIR MOX430-17HFN1-MT0WvsStar Air Kontrol SAK-18-CT2/220V

Side-by-side heat pump comparison

DIRECT AIR MOX430-17HFN1-MT0W

SEER2

18–20.5BTU/Wh

HSPF2

9.5–10BTU/Wh

Cooling Capacity

16000–17000BTU/hr

Cold Climate

Yes

Cold climate certified

Star Air Kontrol SAK-18-CT2/220V

SEER2

20.7BTU/Wh

HSPF2

11.4BTU/Wh

Cooling Capacity

16800BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Both models are closely matched on seer2: 20.5 vs 20.7 BTU/Wh. The DIRECT AIR MOX430-17HFN1-MT0W is larger at 17000 BTU/hr versus 16800 BTU/hr. Star Air Kontrol SAK-18-CT2/220V uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088).

Efficiency

SpecDIRECT AIRStar Air Kontrol
SEER2 (best combination)(BTU/Wh)20.520.7
SEER2 (worst combination)(BTU/Wh)1820.7
HSPF2 (best combination)(BTU/Wh)1011.4
HSPF2 (worst combination)(BTU/Wh)9.511.4
EER2 (best combination)(BTU/Wh)12.512.5
COP at 5 °F1.902.20

Capacity

SpecDIRECT AIRStar Air Kontrol
Cooling Capacity (max)(BTU/hr)1700016800
Cooling Capacity (min)(BTU/hr)1600016800
Heating at 47 °F(BTU/hr)1900018000
Heating at 17 °F(BTU/hr)1560013900
Heating at 5 °F(BTU/hr)1770012800

Configuration

SpecDIRECT AIRStar Air Kontrol
Product TypeHP - Mini or Multi SplitHP - Mini or Multi Split
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesMO seriesSAK Series
Indoor-Unit Combinations Rated41

Refrigerant

SpecDIRECT AIRStar Air Kontrol
TypeR-410AR-454B
GWP RatingR-410A (GWP:2088)R-454B (GWP:470 | Lower GWP)

More comparisons