SpecDirectory

Endura HBEFLM2-OD18vsHaier 1U18EH2HE**

Side-by-side heat pump comparison

Endura HBEFLM2-OD18

SEER2

17.5–22BTU/Wh

HSPF2

9.4–10BTU/Wh

Cooling Capacity

18000BTU/hr

Cold Climate

Yes

Cold climate certified

Haier 1U18EH2HE**

SEER2

23BTU/Wh

HSPF2

12BTU/Wh

Cooling Capacity

17800BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Haier 1U18EH2HE** is 4% more efficient at 23.0 BTU/Wh versus 22.0 BTU/Wh for the Endura HBEFLM2-OD18. The Endura HBEFLM2-OD18 is larger at 18000 BTU/hr versus 17800 BTU/hr. Endura HBEFLM2-OD18 uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088).

Efficiency

SpecEnduraHaier
SEER2 (best combination)(BTU/Wh)2223
SEER2 (worst combination)(BTU/Wh)17.523
HSPF2 (best combination)(BTU/Wh)1012
HSPF2 (worst combination)(BTU/Wh)9.412
EER2 (best combination)(BTU/Wh)13.313
COP at 5 °F1.991.90

Capacity

SpecEnduraHaier
Cooling Capacity (max)(BTU/hr)1800017800
Cooling Capacity (min)(BTU/hr)1800017800
Heating at 47 °F(BTU/hr)1800020000
Heating at 17 °F(BTU/hr)1190015300
Heating at 5 °F(BTU/hr)1800018000

Configuration

SpecEnduraHaier
Product TypeHP - Mini or Multi SplitHP - Mini or Multi Split
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesHB Endura Flex MultiArctic
Indoor-Unit Combinations Rated31

Refrigerant

SpecEnduraHaier
TypeR-454BR-410A
GWP RatingR-454B (GWP:470 | Lower GWP)R-410A (GWP:2088)

More comparisons