Grandaire W4H7T60*K*AAA*

SEER2

16.5BTU/Wh

HSPF2

8.1BTU/Wh

Cooling Capacity

56000BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

Wells WDHP-4860T-G

SEER2

17–17.5BTU/Wh

HSPF2

8.6–9BTU/Wh

Cooling Capacity

47500–55500BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Wells WDHP-4860T-G is 6% more efficient at 17.5 BTU/Wh versus 16.5 BTU/Wh for the Grandaire W4H7T60*K*AAA*. The Grandaire W4H7T60*K*AAA* is larger at 56000 BTU/hr versus 55500 BTU/hr. Wells WDHP-4860T-G uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088).

Efficiency

SpecGrandaireWells
SEER2 (best combination)(BTU/Wh)16.517.5
SEER2 (worst combination)(BTU/Wh)16.517
HSPF2 (best combination)(BTU/Wh)8.19
HSPF2 (worst combination)(BTU/Wh)8.18.6
EER2 (best combination)(BTU/Wh)12.511.3
COP at 5 °F—2.10

Capacity

SpecGrandaireWells
Cooling Capacity (max)(BTU/hr)5600055500
Cooling Capacity (min)(BTU/hr)5600047500
Heating at 47 °F(BTU/hr)5800057000
Heating at 17 °F(BTU/hr)3700042000
Heating at 5 °F(BTU/hr)—42500

Configuration

SpecGrandaireWells
Product TypeHP - Split SystemHP - Split System
Compressor StagingTwo-stageContinuously variable
Cold Climate CertifiedNoYes
Connected CapabilityNoNo
Series2-STAGE 17 SEER HPDucted Central Air
Indoor-Unit Combinations Rated12

Refrigerant

SpecGrandaireWells
TypeR-410AR-454B
GWP RatingR-410A (GWP:2088)R-454B (GWP:470 | Lower GWP)