SpecDirectory

Grandaire W5H8T48*K*AAA*vsLG KUMXB541A

Side-by-side heat pump comparison

Grandaire W5H8T48*K*AAA*

SEER2

15.2–18BTU/Wh

HSPF2

7.8–8.5BTU/Wh

Cooling Capacity

46000–50000BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

LG KUMXB541A

SEER2

18.5–20.6BTU/Wh

HSPF2

9.3–9.5BTU/Wh

Cooling Capacity

50500BTU/hr

Refrigerant

R-32

GWP 675 · Lower

Key differences

LG KUMXB541A is 13% more efficient at 20.6 BTU/Wh versus 18.0 BTU/Wh for the Grandaire W5H8T48*K*AAA*. The LG KUMXB541A is larger at 50500 BTU/hr versus 50000 BTU/hr. Grandaire W5H8T48*K*AAA* uses a lower-impact refrigerant: R-454B (GWP 470) versus R-32 (GWP 675).

Efficiency

SpecGrandaireLG
SEER2 (best combination)(BTU/Wh)1820.6
SEER2 (worst combination)(BTU/Wh)15.218.5
HSPF2 (best combination)(BTU/Wh)8.59.5
HSPF2 (worst combination)(BTU/Wh)7.89.3
EER2 (best combination)(BTU/Wh)13.512.6
COP at 5 °F2.322.19

Capacity

SpecGrandaireLG
Cooling Capacity (max)(BTU/hr)5000050500
Cooling Capacity (min)(BTU/hr)4600050500
Heating at 47 °F(BTU/hr)5200058000
Heating at 17 °F(BTU/hr)3240037200
Heating at 5 °F(BTU/hr)2620041000

Configuration

SpecGrandaireLG
Product TypeHP - Split SystemHP - Mini or Multi Split
Compressor StagingTwo-stageContinuously variable
Cold Climate CertifiedNoNo
Connected CapabilityNoNo
Series2-STAGE 18 SEER HPKUMXB541A
Indoor-Unit Combinations Rated1063

Refrigerant

SpecGrandaireLG
TypeR-454BR-32
GWP RatingR-454B (GWP:470 | Lower GWP)R-32 (GWP:675 | Lower GWP)