SpecDirectory

Guardian RHP15042B21vsTrane N5HP5042A1

Side-by-side heat pump comparison

Guardian RHP15042B21

SEER2

15.2–16BTU/Wh

HSPF2

7.8–8.1BTU/Wh

Cooling Capacity

39500–41500BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

Trane N5HP5042A1

SEER2

15.2–16BTU/Wh

HSPF2

7.8–8.1BTU/Wh

Cooling Capacity

38000–41000BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

Key differences

The Guardian RHP15042B21 is larger at 41500 BTU/hr versus 41000 BTU/hr. Trane N5HP5042A1 uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088).

Efficiency

SpecGuardianTrane
SEER2 (best combination)(BTU/Wh)1616
SEER2 (worst combination)(BTU/Wh)15.215.2
HSPF2 (best combination)(BTU/Wh)8.18.1
HSPF2 (worst combination)(BTU/Wh)7.87.8
EER2 (best combination)(BTU/Wh)1212
COP at 5 °F2.382.28

Capacity

SpecGuardianTrane
Cooling Capacity (max)(BTU/hr)4150041000
Cooling Capacity (min)(BTU/hr)3950038000
Heating at 47 °F(BTU/hr)4050039000
Heating at 17 °F(BTU/hr)2660026200
Heating at 5 °F(BTU/hr)2240019900

Configuration

SpecGuardianTrane
Product TypeHP - Split SystemHP - Split System
Compressor StagingTwo-stageSingle stage
Cold Climate CertifiedNoNo
Connected CapabilityNoNo
SeriesLX SERIESAdvantage 15 Heat Pump
Indoor-Unit Combinations Rated2772

Refrigerant

SpecGuardianTrane
TypeR-410AR-454B
GWP RatingR-410A (GWP:2088)R-454B (GWP:470 | Lower GWP)