SpecDirectory

Haier 1Q12TE2BE**vsMitsubishi Electric SUZ-CA12NLH***

Side-by-side heat pump comparison

Haier 1Q12TE2BE**

SEER2

21BTU/Wh

HSPF2

9.5BTU/Wh

Cooling Capacity

11800BTU/hr

Cold Climate

Yes

Cold climate certified

Mitsubishi Electric SUZ-CA12NLH***

SEER2

18.4–20.7BTU/Wh

HSPF2

8.5–9.8BTU/Wh

Cooling Capacity

11300–12000BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

Key differences

Both models are closely matched on seer2: 21.0 vs 20.7 BTU/Wh. The Mitsubishi Electric SUZ-CA12NLH*** is larger at 12000 BTU/hr versus 11800 BTU/hr.

Efficiency

SpecHaierMitsubishi Electric
SEER2 (best combination)(BTU/Wh)2120.7
SEER2 (worst combination)(BTU/Wh)2118.4
HSPF2 (best combination)(BTU/Wh)9.59.8
HSPF2 (worst combination)(BTU/Wh)9.58.5
EER2 (best combination)(BTU/Wh)1212.6
COP at 5 °F1.802.20

Capacity

SpecHaierMitsubishi Electric
Cooling Capacity (max)(BTU/hr)1180012000
Cooling Capacity (min)(BTU/hr)1180011300
Heating at 47 °F(BTU/hr)1300015000
Heating at 17 °F(BTU/hr)78009800
Heating at 5 °F(BTU/hr)104007900

Configuration

SpecHaierMitsubishi Electric
Product TypeHP - Mini or Multi SplitHP - Mini or Multi Split
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesNo
Connected CapabilityNoNo
SeriesTempo 230VM series
Indoor-Unit Combinations Rated16

Refrigerant

SpecHaierMitsubishi Electric
TypeR-454BR-454B
GWP RatingR-454B (GWP:470 | Lower GWP)R-454B (GWP:470 | Lower GWP)