SpecDirectory

Haier 1U18EH2HE**vsHitachi PAS-18BUFASDQ1-LAC

Side-by-side heat pump comparison

Haier 1U18EH2HE**

SEER2

23BTU/Wh

HSPF2

12BTU/Wh

Cooling Capacity

17800BTU/hr

Cold Climate

Yes

Cold climate certified

Hitachi PAS-18BUFASDQ1-LAC

SEER2

21–27BTU/Wh

HSPF2

9.5–11BTU/Wh

Cooling Capacity

18000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Hitachi PAS-18BUFASDQ1-LAC is 15% more efficient at 27.0 BTU/Wh versus 23.0 BTU/Wh for the Haier 1U18EH2HE**. The Hitachi PAS-18BUFASDQ1-LAC is larger at 18000 BTU/hr versus 17800 BTU/hr. Hitachi PAS-18BUFASDQ1-LAC uses a lower-impact refrigerant: R-32 (GWP 675) versus R-410A (GWP 2088). Overall, the Hitachi PAS-18BUFASDQ1-LAC sits higher in the category, ranking above 96% of certified air-source heat pumps.

Efficiency

SpecHaierHitachi
SEER2 (best combination)(BTU/Wh)2327
SEER2 (worst combination)(BTU/Wh)2321
HSPF2 (best combination)(BTU/Wh)1211
HSPF2 (worst combination)(BTU/Wh)129.5
EER2 (best combination)(BTU/Wh)1315
COP at 5 °F1.902.60

Capacity

SpecHaierHitachi
Cooling Capacity (max)(BTU/hr)1780018000
Cooling Capacity (min)(BTU/hr)1780018000
Heating at 47 °F(BTU/hr)2000018000
Heating at 17 °F(BTU/hr)1530019000
Heating at 5 °F(BTU/hr)1800015000

Configuration

SpecHaierHitachi
Product TypeHP - Mini or Multi SplitHP - Mini or Multi Split
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesArcticairCore700
Indoor-Unit Combinations Rated14

Refrigerant

SpecHaierHitachi
TypeR-410AR-32
GWP RatingR-410A (GWP:2088)R-32 (GWP:675 | Lower GWP)

More comparisons