SpecDirectory

Haier 1U18EH2HE**vsJetson HP-18ODU-001

Side-by-side heat pump comparison

Haier 1U18EH2HE**

SEER2

23BTU/Wh

HSPF2

12BTU/Wh

Cooling Capacity

17800BTU/hr

Cold Climate

Yes

Cold climate certified

Jetson HP-18ODU-001

SEER2

17BTU/Wh

HSPF2

9.3BTU/Wh

Cooling Capacity

18000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Haier 1U18EH2HE** is 26% more efficient at 23.0 BTU/Wh versus 17.0 BTU/Wh for the Jetson HP-18ODU-001. The Jetson HP-18ODU-001 is larger at 18000 BTU/hr versus 17800 BTU/hr. Jetson HP-18ODU-001 uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088).

Efficiency

SpecHaierJetson
SEER2 (best combination)(BTU/Wh)2317
SEER2 (worst combination)(BTU/Wh)2317
HSPF2 (best combination)(BTU/Wh)129.3
HSPF2 (worst combination)(BTU/Wh)129.3
EER2 (best combination)(BTU/Wh)1312
COP at 5 °F1.901.95

Capacity

SpecHaierJetson
Cooling Capacity (max)(BTU/hr)1780018000
Cooling Capacity (min)(BTU/hr)1780018000
Heating at 47 °F(BTU/hr)2000018000
Heating at 17 °F(BTU/hr)1530015600
Heating at 5 °F(BTU/hr)1800018000

Configuration

SpecHaierJetson
Product TypeHP - Mini or Multi SplitHP - Split System
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesArcticHP Series
Indoor-Unit Combinations Rated12

Refrigerant

SpecHaierJetson
TypeR-410AR-454B
GWP RatingR-410A (GWP:2088)R-454B (GWP:470 | Lower GWP)