SpecDirectory

Haier 1U18EH2HE**vsSamsung AC018DXADCG

Side-by-side heat pump comparison

Haier 1U18EH2HE**

SEER2

23BTU/Wh

HSPF2

12BTU/Wh

Cooling Capacity

17800BTU/hr

Cold Climate

Yes

Cold climate certified

Samsung AC018DXADCG

SEER2

16.5–23.8BTU/Wh

HSPF2

8.1–9.3BTU/Wh

Cooling Capacity

18000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Samsung AC018DXADCG is 3% more efficient at 23.8 BTU/Wh versus 23.0 BTU/Wh for the Haier 1U18EH2HE**. The Samsung AC018DXADCG is larger at 18000 BTU/hr versus 17800 BTU/hr. Samsung AC018DXADCG uses a lower-impact refrigerant: R-32 (GWP 675) versus R-410A (GWP 2088). Overall, the Samsung AC018DXADCG sits higher in the category, ranking above 84% of certified air-source heat pumps.

Efficiency

SpecHaierSamsung
SEER2 (best combination)(BTU/Wh)2323.8
SEER2 (worst combination)(BTU/Wh)2316.5
HSPF2 (best combination)(BTU/Wh)129.3
HSPF2 (worst combination)(BTU/Wh)128.1
EER2 (best combination)(BTU/Wh)1313
COP at 5 °F1.901.80

Capacity

SpecHaierSamsung
Cooling Capacity (max)(BTU/hr)1780018000
Cooling Capacity (min)(BTU/hr)1780018000
Heating at 47 °F(BTU/hr)2000020000
Heating at 17 °F(BTU/hr)1530012700
Heating at 5 °F(BTU/hr)1800016000

Configuration

SpecHaierSamsung
Product TypeHP - Mini or Multi SplitHP - Mini or Multi Split
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesArcticMulti-Position Air Handler - Standard (CAC)
Indoor-Unit Combinations Rated13

Refrigerant

SpecHaierSamsung
TypeR-410AR-32
GWP RatingR-410A (GWP:2088)R-32 (GWP:675 | Lower GWP)

More comparisons