SpecDirectory

Haier 1U18EH2HE**vsSUPREME T55-SUPAE18E454

Side-by-side heat pump comparison

Haier 1U18EH2HE**

SEER2

23BTU/Wh

HSPF2

12BTU/Wh

Cooling Capacity

17800BTU/hr

Cold Climate

Yes

Cold climate certified

SUPREME T55-SUPAE18E454

SEER2

21.4BTU/Wh

HSPF2

11BTU/Wh

Cooling Capacity

18000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Haier 1U18EH2HE** is 7% more efficient at 23.0 BTU/Wh versus 21.4 BTU/Wh for the SUPREME T55-SUPAE18E454. The SUPREME T55-SUPAE18E454 is larger at 18000 BTU/hr versus 17800 BTU/hr. SUPREME T55-SUPAE18E454 uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088).

Efficiency

SpecHaierSUPREME
SEER2 (best combination)(BTU/Wh)2321.4
SEER2 (worst combination)(BTU/Wh)2321.4
HSPF2 (best combination)(BTU/Wh)1211
HSPF2 (worst combination)(BTU/Wh)1211
EER2 (best combination)(BTU/Wh)1312.5
COP at 5 °F1.901.92

Capacity

SpecHaierSUPREME
Cooling Capacity (max)(BTU/hr)1780018000
Cooling Capacity (min)(BTU/hr)1780018000
Heating at 47 °F(BTU/hr)2000018000
Heating at 17 °F(BTU/hr)1530018000
Heating at 5 °F(BTU/hr)1800018000

Configuration

SpecHaierSUPREME
Product TypeHP - Mini or Multi SplitHP - Mini or Multi Split
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesArcticT55 Series
Indoor-Unit Combinations Rated11

Refrigerant

SpecHaierSUPREME
TypeR-410AR-454B
GWP RatingR-410A (GWP:2088)R-454B (GWP:470 | Lower GWP)

More comparisons