SpecDirectory

Haier 1U18EH2HE**vsYork YRACDJ18WHBA

Side-by-side heat pump comparison

Haier 1U18EH2HE**

SEER2

23BTU/Wh

HSPF2

12BTU/Wh

Cooling Capacity

17800BTU/hr

Cold Climate

Yes

Cold climate certified

York YRACDJ18WHBA

SEER2

19.5BTU/Wh

HSPF2

10.5BTU/Wh

Cooling Capacity

18000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Haier 1U18EH2HE** is 15% more efficient at 23.0 BTU/Wh versus 19.5 BTU/Wh for the York YRACDJ18WHBA. The York YRACDJ18WHBA is larger at 18000 BTU/hr versus 17800 BTU/hr. York YRACDJ18WHBA uses a lower-impact refrigerant: R-32 (GWP 675) versus R-410A (GWP 2088).

Efficiency

SpecHaierYork
SEER2 (best combination)(BTU/Wh)2319.5
SEER2 (worst combination)(BTU/Wh)2319.5
HSPF2 (best combination)(BTU/Wh)1210.5
HSPF2 (worst combination)(BTU/Wh)1210.5
EER2 (best combination)(BTU/Wh)1312
COP at 5 °F1.901.90

Capacity

SpecHaierYork
Cooling Capacity (max)(BTU/hr)1780018000
Cooling Capacity (min)(BTU/hr)1780018000
Heating at 47 °F(BTU/hr)2000018000
Heating at 17 °F(BTU/hr)1530013300
Heating at 5 °F(BTU/hr)1800014200

Configuration

SpecHaierYork
Product TypeHP - Mini or Multi SplitHP - Mini or Multi Split
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesArcticY400
Indoor-Unit Combinations Rated11

Refrigerant

SpecHaierYork
TypeR-410AR-32
GWP RatingR-410A (GWP:2088)R-32 (GWP:675 | Lower GWP)