HAXXAIR HVHM-24T2DvsViessmann D5CURAH24AAK+KSAIC0701230
Side-by-side heat pump comparison
HAXXAIR HVHM-24T2D
SEER2
21–22BTU/Wh
HSPF2
8.6–9.1BTU/Wh
Cooling Capacity
24000BTU/hr
Cold Climate
Yes
Cold climate certified
Viessmann D5CURAH24AAK+KSAIC0701230
SEER2
16BTU/Wh
HSPF2
9BTU/Wh
Cooling Capacity
23800BTU/hr
Cold Climate
Yes
Cold climate certified
Key differences
HAXXAIR HVHM-24T2D is 27% more efficient at 22.0 BTU/Wh versus 16.0 BTU/Wh for the Viessmann D5CURAH24AAK+KSAIC0701230. The HAXXAIR HVHM-24T2D is larger at 24000 BTU/hr versus 23800 BTU/hr. Viessmann D5CURAH24AAK+KSAIC0701230 uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088). Overall, the HAXXAIR HVHM-24T2D sits higher in the category, ranking above 44% of certified air-source heat pumps.
Efficiency
| Spec | HAXXAIR | Viessmann |
|---|---|---|
| SEER2 (best combination)(BTU/Wh) | 22 | 16 |
| SEER2 (worst combination)(BTU/Wh) | 21 | 16 |
| HSPF2 (best combination)(BTU/Wh) | 9.1 | 9 |
| HSPF2 (worst combination)(BTU/Wh) | 8.6 | 9 |
| EER2 (best combination)(BTU/Wh) | 12.5 | 10 |
| COP at 5 °F | 1.84 | 1.98 |
Capacity
| Spec | HAXXAIR | Viessmann |
|---|---|---|
| Cooling Capacity (max)(BTU/hr) | 24000 | 23800 |
| Cooling Capacity (min)(BTU/hr) | 24000 | 23800 |
| Heating at 47 °F(BTU/hr) | 24000 | 25400 |
| Heating at 17 °F(BTU/hr) | 15000 | 19400 |
| Heating at 5 °F(BTU/hr) | 24000 | 19800 |
Configuration
| Spec | HAXXAIR | Viessmann |
|---|---|---|
| Product Type | HP - Mini or Multi Split | HP - Split System |
| Compressor Staging | Continuously variable | Continuously variable |
| Cold Climate Certified | Yes | Yes |
| Connected Capability | No | No |
| Series | Hi MULTI Xtreme | Crossover Heat Pump |
| Indoor-Unit Combinations Rated | 3 | 1 |
Refrigerant
| Spec | HAXXAIR | Viessmann |
|---|---|---|
| Type | R-410A | R-454B |
| GWP Rating | R-410A (GWP:2088) | R-454B (GWP:470 | Lower GWP) |