Heil D5CURAH48AAK

SEER2

15.2–16BTU/Wh

HSPF2

8.5–9BTU/Wh

Cooling Capacity

45000–48000BTU/hr

Cold Climate

Yes

Cold climate certified

York YZT48B21

SEER2

16–17BTU/Wh

HSPF2

8.1BTU/Wh

Cooling Capacity

45500–47500BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

Key differences

York YZT48B21 is 6% more efficient at 17.0 BTU/Wh versus 16.0 BTU/Wh for the Heil D5CURAH48AAK. The Heil D5CURAH48AAK is larger at 48000 BTU/hr versus 47500 BTU/hr. Heil D5CURAH48AAK uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088). Overall, the York YZT48B21 sits higher in the category, ranking above 85% of certified air-source heat pumps.

Efficiency

SpecHeilYork
SEER2 (best combination)(BTU/Wh)1617
SEER2 (worst combination)(BTU/Wh)15.216
HSPF2 (best combination)(BTU/Wh)98.1
HSPF2 (worst combination)(BTU/Wh)8.58.1
EER2 (best combination)(BTU/Wh)1012.5
COP at 5 °F1.852.32

Capacity

SpecHeilYork
Cooling Capacity (max)(BTU/hr)4800047500
Cooling Capacity (min)(BTU/hr)4500045500
Heating at 47 °F(BTU/hr)4800048000
Heating at 17 °F(BTU/hr)3480033000
Heating at 5 °F(BTU/hr)4000027000

Configuration

SpecHeilYork
Product TypeHP - Split SystemHP - Split System
Compressor StagingContinuously variableTwo-stage
Cold Climate CertifiedYesNo
Connected CapabilityNoNo
SeriesD5F SeriesAFFINITY
Indoor-Unit Combinations Rated218

Refrigerant

SpecHeilYork
TypeR-454BR-410A
GWP RatingR-454B (GWP:470 | Lower GWP)R-410A (GWP:2088)

More comparisons