SpecDirectory

Johnson Controls HL19B4821vsZERO ZOV-48HDTB

Side-by-side heat pump comparison

Johnson Controls HL19B4821

SEER2

16–17BTU/Wh

HSPF2

8.1BTU/Wh

Cooling Capacity

45500–47500BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

ZERO ZOV-48HDTB

SEER2

18BTU/Wh

HSPF2

8.5BTU/Wh

Cooling Capacity

47000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

ZERO ZOV-48HDTB is 6% more efficient at 18.0 BTU/Wh versus 17.0 BTU/Wh for the Johnson Controls HL19B4821. The Johnson Controls HL19B4821 is larger at 47500 BTU/hr versus 47000 BTU/hr. ZERO ZOV-48HDTB uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088).

Efficiency

SpecJohnson ControlsZERO
SEER2 (best combination)(BTU/Wh)1718
SEER2 (worst combination)(BTU/Wh)1618
HSPF2 (best combination)(BTU/Wh)8.18.5
HSPF2 (worst combination)(BTU/Wh)8.18.5
EER2 (best combination)(BTU/Wh)12.59
COP at 5 °F2.321.80

Capacity

SpecJohnson ControlsZERO
Cooling Capacity (max)(BTU/hr)4750047000
Cooling Capacity (min)(BTU/hr)4550047000
Heating at 47 °F(BTU/hr)4800047000
Heating at 17 °F(BTU/hr)3300035000
Heating at 5 °F(BTU/hr)2700033000

Configuration

SpecJohnson ControlsZERO
Product TypeHP - Split SystemHP - Split System
Compressor StagingTwo-stageContinuously variable
Cold Climate CertifiedNoYes
Connected CapabilityNoNo
SeriesMOMENTUMZ-MAX
Indoor-Unit Combinations Rated171

Refrigerant

SpecJohnson ControlsZERO
TypeR-410AR-454B
GWP RatingR-410A (GWP:2088)R-454B (GWP:470 | Lower GWP)

More comparisons