KARDA 3KARDA48MZ5

SEER2

21.1BTU/Wh

HSPF2

9.5BTU/Wh

Cooling Capacity

48000BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

York YZT48B21

SEER2

16–17BTU/Wh

HSPF2

8.1BTU/Wh

Cooling Capacity

45500–47500BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

Key differences

KARDA 3KARDA48MZ5 is 19% more efficient at 21.1 BTU/Wh versus 17.0 BTU/Wh for the York YZT48B21. The KARDA 3KARDA48MZ5 is larger at 48000 BTU/hr versus 47500 BTU/hr.

Efficiency

SpecKARDAYork
SEER2 (best combination)(BTU/Wh)21.117
SEER2 (worst combination)(BTU/Wh)21.116
HSPF2 (best combination)(BTU/Wh)9.58.1
HSPF2 (worst combination)(BTU/Wh)9.58.1
EER2 (best combination)(BTU/Wh)1112.5
COP at 5 °F1.802.32

Capacity

SpecKARDAYork
Cooling Capacity (max)(BTU/hr)4800047500
Cooling Capacity (min)(BTU/hr)4800045500
Heating at 47 °F(BTU/hr)4800048000
Heating at 17 °F(BTU/hr)3600033000
Heating at 5 °F(BTU/hr)3300027000

Configuration

SpecKARDAYork
Product TypeHP - Mini or Multi SplitHP - Split System
Compressor StagingContinuously variableTwo-stage
Cold Climate CertifiedNoNo
Connected CapabilityNoNo
Series3KAR seriesAFFINITY
Indoor-Unit Combinations Rated118

Refrigerant

SpecKARDAYork
TypeR-410AR-410A
GWP RatingR-410A (GWP:2088)R-410A (GWP:2088)