Keeprite C5H3V60*K*AAA*vsTrane 5DCZ5060A1
Side-by-side heat pump comparison
Keeprite C5H3V60*K*AAA*
SEER2
17–20BTU/Wh
HSPF2
7.8–8.5BTU/Wh
Cooling Capacity
55000–58000BTU/hr
Cold Climate
Yes
Cold climate certified
Trane 5DCZ5060A1
SEER2
15.2BTU/Wh
HSPF2
7.2BTU/Wh
Cooling Capacity
57500BTU/hr
Refrigerant
R-454B
GWP 470 · Lower
Key differences
Keeprite C5H3V60*K*AAA* is 24% more efficient at 20.0 BTU/Wh versus 15.2 BTU/Wh for the Trane 5DCZ5060A1. The Keeprite C5H3V60*K*AAA* is larger at 58000 BTU/hr versus 57500 BTU/hr. Overall, the Keeprite C5H3V60*K*AAA* sits higher in the category, ranking above 99% of certified air-source heat pumps.
Efficiency
| Spec | Keeprite | Trane |
|---|---|---|
| SEER2 (best combination)(BTU/Wh) | 20 | 15.2 |
| SEER2 (worst combination)(BTU/Wh) | 17 | 15.2 |
| HSPF2 (best combination)(BTU/Wh) | 8.5 | 7.2 |
| HSPF2 (worst combination)(BTU/Wh) | 7.8 | 7.2 |
| EER2 (best combination)(BTU/Wh) | 12.5 | 11.5 |
| COP at 5 °F | 2.08 | 2 |
Capacity
| Spec | Keeprite | Trane |
|---|---|---|
| Cooling Capacity (max)(BTU/hr) | 58000 | 57500 |
| Cooling Capacity (min)(BTU/hr) | 55000 | 57500 |
| Heating at 47 °F(BTU/hr) | 63500 | 56500 |
| Heating at 17 °F(BTU/hr) | 49000 | 37000 |
| Heating at 5 °F(BTU/hr) | 47500 | 29600 |
Configuration
| Spec | Keeprite | Trane |
|---|---|---|
| Product Type | HP - Split System | HP - Single Package |
| Compressor Staging | Continuously variable | Two-stage |
| Cold Climate Certified | Yes | No |
| Connected Capability | No | No |
| Series | ProComfort 23 VS HP | 5DCZ5 |
| Indoor-Unit Combinations Rated | 55 | 1 |
Refrigerant
| Spec | Keeprite | Trane |
|---|---|---|
| Type | R-454B | R-454B |
| GWP Rating | R-454B (GWP:470 | Lower GWP) | R-454B (GWP:470 | Lower GWP) |