SpecDirectory

LPS Legacy H4H7T60*K*AAA*vsYork YH960E2C11

Side-by-side heat pump comparison

LPS Legacy H4H7T60*K*AAA*

SEER2

16BTU/Wh

HSPF2

8.1BTU/Wh

Cooling Capacity

56500BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

York YH960E2C11

SEER2

19–22BTU/Wh

HSPF2

8.5–9BTU/Wh

Cooling Capacity

47000–56000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

York YH960E2C11 is 27% more efficient at 22.0 BTU/Wh versus 16.0 BTU/Wh for the LPS Legacy H4H7T60*K*AAA*. The LPS Legacy H4H7T60*K*AAA* is larger at 56500 BTU/hr versus 56000 BTU/hr. York YH960E2C11 uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088). Overall, the York YH960E2C11 sits higher in the category, ranking above 97% of certified air-source heat pumps.

Efficiency

SpecLPS LegacyYork
SEER2 (best combination)(BTU/Wh)1622
SEER2 (worst combination)(BTU/Wh)1619
HSPF2 (best combination)(BTU/Wh)8.19
HSPF2 (worst combination)(BTU/Wh)8.18.5
EER2 (best combination)(BTU/Wh)1212
COP at 5 °F—2

Capacity

SpecLPS LegacyYork
Cooling Capacity (max)(BTU/hr)5650056000
Cooling Capacity (min)(BTU/hr)5650047000
Heating at 47 °F(BTU/hr)5800059000
Heating at 17 °F(BTU/hr)3680047500
Heating at 5 °F(BTU/hr)—45000

Configuration

SpecLPS LegacyYork
Product TypeHP - Split SystemHP - Split System
Compressor StagingTwo-stageContinuously variable
Cold Climate CertifiedNoYes
Connected CapabilityNoNo
SeriesMainline 17 SEER2 HPLX SERIES
Indoor-Unit Combinations Rated1197

Refrigerant

SpecLPS LegacyYork
TypeR-410AR-454B
GWP RatingR-410A (GWP:2088)R-454B (GWP:470 | Lower GWP)

More comparisons