SpecDirectory

Mitsubishi Electric PUMY-HL60NKMU***vsWEATHERMAKER PH8TAN560**AA*

Side-by-side heat pump comparison

Mitsubishi Electric PUMY-HL60NKMU***

SEER2

16.4–20BTU/Wh

HSPF2

10–10.9BTU/Wh

Cooling Capacity

60000BTU/hr

Cold Climate

Yes

Cold climate certified

WEATHERMAKER PH8TAN560**AA*

SEER2

16–17.5BTU/Wh

HSPF2

8–8.5BTU/Wh

Cooling Capacity

54000–58000BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

Key differences

Mitsubishi Electric PUMY-HL60NKMU*** is 13% more efficient at 20.0 BTU/Wh versus 17.5 BTU/Wh for the WEATHERMAKER PH8TAN560**AA*. The Mitsubishi Electric PUMY-HL60NKMU*** is larger at 60000 BTU/hr versus 58000 BTU/hr.

Efficiency

SpecMitsubishi ElectricWEATHERMAKER
SEER2 (best combination)(BTU/Wh)2017.5
SEER2 (worst combination)(BTU/Wh)16.416
HSPF2 (best combination)(BTU/Wh)10.98.5
HSPF2 (worst combination)(BTU/Wh)108
EER2 (best combination)(BTU/Wh)1213
COP at 5 °F22.34

Capacity

SpecMitsubishi ElectricWEATHERMAKER
Cooling Capacity (max)(BTU/hr)6000058000
Cooling Capacity (min)(BTU/hr)6000054000
Heating at 47 °F(BTU/hr)6600061500
Heating at 17 °F(BTU/hr)4450038500
Heating at 5 °F(BTU/hr)6200031800

Configuration

SpecMitsubishi ElectricWEATHERMAKER
Product TypeHP - Mini or Multi SplitHP - Split System
Compressor StagingContinuously variableTwo-stage
Cold Climate CertifiedYesNo
Connected CapabilityNoNo
SeriesCity Multi2-STAGE 18 SEER HP
Indoor-Unit Combinations Rated349

Refrigerant

SpecMitsubishi ElectricWEATHERMAKER
TypeR-454BR-454B
GWP RatingR-454B (GWP:470 | Lower GWP)R-454B (GWP:470 | Lower GWP)

More comparisons