SpecDirectory

SINCLAIR AIR CONDITIONING BH719M36P-**AvsSLIMAIR SHC4Z36VE2AG

Side-by-side heat pump comparison

SINCLAIR AIR CONDITIONING BH719M36P-**A

SEER2

15.2–20BTU/Wh

HSPF2

7.8–8.5BTU/Wh

Cooling Capacity

21600–35800BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

SLIMAIR SHC4Z36VE2AG

SEER2

19–20BTU/Wh

HSPF2

9.7–10BTU/Wh

Cooling Capacity

36000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

The SLIMAIR SHC4Z36VE2AG is larger at 36000 BTU/hr versus 35800 BTU/hr. SINCLAIR AIR CONDITIONING BH719M36P-**A uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088).

Efficiency

SpecSINCLAIR AIR CONDITIONINGSLIMAIR
SEER2 (best combination)(BTU/Wh)2020
SEER2 (worst combination)(BTU/Wh)15.219
HSPF2 (best combination)(BTU/Wh)8.510
HSPF2 (worst combination)(BTU/Wh)7.89.7
EER2 (best combination)(BTU/Wh)13.212.5
COP at 5 °F2.121.90

Capacity

SpecSINCLAIR AIR CONDITIONINGSLIMAIR
Cooling Capacity (max)(BTU/hr)3580036000
Cooling Capacity (min)(BTU/hr)2160036000
Heating at 47 °F(BTU/hr)3600037000
Heating at 17 °F(BTU/hr)2160035000
Heating at 5 °F(BTU/hr)1700036000

Configuration

SpecSINCLAIR AIR CONDITIONINGSLIMAIR
Product TypeHP - Split SystemHP - Mini or Multi Split
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedNoYes
Connected CapabilityNoNo
SeriesBH719M SERIESSHC Series
Indoor-Unit Combinations Rated1443

Refrigerant

SpecSINCLAIR AIR CONDITIONINGSLIMAIR
TypeR-454BR-410A
GWP RatingR-454B (GWP:470 | Lower GWP)R-410A (GWP:2088)