SpecDirectory

SINCLAIR AIR CONDITIONING BH719M36P-**AvsTempstar DLCURAH36ABK

Side-by-side heat pump comparison

SINCLAIR AIR CONDITIONING BH719M36P-**A

SEER2

15.2–20BTU/Wh

HSPF2

7.8–8.5BTU/Wh

Cooling Capacity

21600–35800BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

Tempstar DLCURAH36ABK

SEER2

15.2–16BTU/Wh

HSPF2

8.6–10BTU/Wh

Cooling Capacity

35000–36000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

SINCLAIR AIR CONDITIONING BH719M36P-**A is 20% more efficient at 20.0 BTU/Wh versus 16.0 BTU/Wh for the Tempstar DLCURAH36ABK. The Tempstar DLCURAH36ABK is larger at 36000 BTU/hr versus 35800 BTU/hr. SINCLAIR AIR CONDITIONING BH719M36P-**A uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088). Overall, the SINCLAIR AIR CONDITIONING BH719M36P-**A sits higher in the category, ranking above 70% of certified air-source heat pumps.

Efficiency

SpecSINCLAIR AIR CONDITIONINGTempstar
SEER2 (best combination)(BTU/Wh)2016
SEER2 (worst combination)(BTU/Wh)15.215.2
HSPF2 (best combination)(BTU/Wh)8.510
HSPF2 (worst combination)(BTU/Wh)7.88.6
EER2 (best combination)(BTU/Wh)13.210
COP at 5 °F2.122

Capacity

SpecSINCLAIR AIR CONDITIONINGTempstar
Cooling Capacity (max)(BTU/hr)3580036000
Cooling Capacity (min)(BTU/hr)2160035000
Heating at 47 °F(BTU/hr)3600040000
Heating at 17 °F(BTU/hr)2160033000
Heating at 5 °F(BTU/hr)1700034400

Configuration

SpecSINCLAIR AIR CONDITIONINGTempstar
Product TypeHP - Split SystemHP - Split System
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedNoYes
Connected CapabilityNoNo
SeriesBH719M SERIESDL series
Indoor-Unit Combinations Rated1444

Refrigerant

SpecSINCLAIR AIR CONDITIONINGTempstar
TypeR-454BR-410A
GWP RatingR-454B (GWP:470 | Lower GWP)R-410A (GWP:2088)