SINCLAIR AIR CONDITIONING BH719M36P-**AvsViessmann D5CUHAH36AAK
Side-by-side heat pump comparison
SINCLAIR AIR CONDITIONING BH719M36P-**A
SEER2
15.2–20BTU/Wh
HSPF2
7.8–8.5BTU/Wh
Cooling Capacity
21600–35800BTU/hr
Refrigerant
R-454B
GWP 470 · Lower
Viessmann D5CUHAH36AAK
SEER2
15.8–18BTU/Wh
HSPF2
9.4–10.3BTU/Wh
Cooling Capacity
36000BTU/hr
Cold Climate
Yes
Cold climate certified
Key differences
SINCLAIR AIR CONDITIONING BH719M36P-**A is 10% more efficient at 20.0 BTU/Wh versus 18.0 BTU/Wh for the Viessmann D5CUHAH36AAK. The Viessmann D5CUHAH36AAK is larger at 36000 BTU/hr versus 35800 BTU/hr.
Efficiency
| Spec | SINCLAIR AIR CONDITIONING | Viessmann |
|---|---|---|
| SEER2 (best combination)(BTU/Wh) | 20 | 18 |
| SEER2 (worst combination)(BTU/Wh) | 15.2 | 15.8 |
| HSPF2 (best combination)(BTU/Wh) | 8.5 | 10.3 |
| HSPF2 (worst combination)(BTU/Wh) | 7.8 | 9.4 |
| EER2 (best combination)(BTU/Wh) | 13.2 | 12 |
| COP at 5 °F | 2.12 | 1.90 |
Capacity
| Spec | SINCLAIR AIR CONDITIONING | Viessmann |
|---|---|---|
| Cooling Capacity (max)(BTU/hr) | 35800 | 36000 |
| Cooling Capacity (min)(BTU/hr) | 21600 | 36000 |
| Heating at 47 °F(BTU/hr) | 36000 | 38000 |
| Heating at 17 °F(BTU/hr) | 21600 | 33000 |
| Heating at 5 °F(BTU/hr) | 17000 | 39000 |
Configuration
| Spec | SINCLAIR AIR CONDITIONING | Viessmann |
|---|---|---|
| Product Type | HP - Split System | HP - Split System |
| Compressor Staging | Continuously variable | Continuously variable |
| Cold Climate Certified | No | Yes |
| Connected Capability | No | No |
| Series | BH719M SERIES | D5C Series |
| Indoor-Unit Combinations Rated | 144 | 5 |
Refrigerant
| Spec | SINCLAIR AIR CONDITIONING | Viessmann |
|---|---|---|
| Type | R-454B | R-454B |
| GWP Rating | R-454B (GWP:470 | Lower GWP) | R-454B (GWP:470 | Lower GWP) |