SpecDirectory

TCL TMH18HEI2NAS0U25*vsWEATHERMAKER PH5SAN519**AA*

Side-by-side heat pump comparison

TCL TMH18HEI2NAS0U25*

SEER2

21.5–27BTU/Wh

HSPF2

9–10BTU/Wh

Cooling Capacity

18000–20000BTU/hr

Cold Climate

Yes

Cold climate certified

WEATHERMAKER PH5SAN519**AA*

SEER2

15.2–16BTU/Wh

HSPF2

7.8–8BTU/Wh

Cooling Capacity

17700–19300BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

Key differences

TCL TMH18HEI2NAS0U25* is 41% more efficient at 27.0 BTU/Wh versus 16.0 BTU/Wh for the WEATHERMAKER PH5SAN519**AA*. The TCL TMH18HEI2NAS0U25* is larger at 20000 BTU/hr versus 19300 BTU/hr. Overall, the TCL TMH18HEI2NAS0U25* sits higher in the category, ranking above 96% of certified air-source heat pumps.

Efficiency

SpecTCLWEATHERMAKER
SEER2 (best combination)(BTU/Wh)2716
SEER2 (worst combination)(BTU/Wh)21.515.2
HSPF2 (best combination)(BTU/Wh)108
HSPF2 (worst combination)(BTU/Wh)97.8
EER2 (best combination)(BTU/Wh)1513
COP at 5 °F22

Capacity

SpecTCLWEATHERMAKER
Cooling Capacity (max)(BTU/hr)2000019300
Cooling Capacity (min)(BTU/hr)1800017700
Heating at 47 °F(BTU/hr)2000019500
Heating at 17 °F(BTU/hr)2300011000
Heating at 5 °F(BTU/hr)198008500

Configuration

SpecTCLWEATHERMAKER
Product TypeHP - Mini or Multi SplitHP - Split System
Compressor StagingContinuously variableSingle stage
Cold Climate CertifiedYesNo
Connected CapabilityNoNo
Seriesfree match 27S HT15 SEER2 HP
Indoor-Unit Combinations Rated350

Refrigerant

SpecTCLWEATHERMAKER
TypeR-454BR-454B
GWP RatingR-454B (GWP:470 | Lower GWP)R-454B (GWP:470 | Lower GWP)

More comparisons