SpecDirectory

Tempstar D5CURAH48AAK+KSAIC0701230vsYork PHG6B481002X4

Side-by-side heat pump comparison

Tempstar D5CURAH48AAK+KSAIC0701230

SEER2

15.5BTU/Wh

HSPF2

8.1BTU/Wh

Cooling Capacity

47000BTU/hr

Cold Climate

Yes

Cold climate certified

York PHG6B481002X4

SEER2

15.2BTU/Wh

HSPF2

7.2BTU/Wh

Cooling Capacity

46500BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

Key differences

Both models are closely matched on seer2: 15.5 vs 15.2 BTU/Wh. The Tempstar D5CURAH48AAK+KSAIC0701230 is larger at 47000 BTU/hr versus 46500 BTU/hr. Tempstar D5CURAH48AAK+KSAIC0701230 uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088). Overall, the Tempstar D5CURAH48AAK+KSAIC0701230 sits higher in the category, ranking above 10% of certified air-source heat pumps.

Efficiency

SpecTempstarYork
SEER2 (best combination)(BTU/Wh)15.515.2
SEER2 (worst combination)(BTU/Wh)15.515.2
HSPF2 (best combination)(BTU/Wh)8.17.2
HSPF2 (worst combination)(BTU/Wh)8.17.2
EER2 (best combination)(BTU/Wh)912
COP at 5 °F1.852.20

Capacity

SpecTempstarYork
Cooling Capacity (max)(BTU/hr)4700046500
Cooling Capacity (min)(BTU/hr)4700046500
Heating at 47 °F(BTU/hr)4700045500
Heating at 17 °F(BTU/hr)3100030200
Heating at 5 °F(BTU/hr)3640024000

Configuration

SpecTempstarYork
Product TypeHP - Split SystemHP - Single Package
Compressor StagingContinuously variableTwo-stage
Cold Climate CertifiedYesNo
Connected CapabilityNoNo
SeriesCrossover Heat PumpLX SERIES
Indoor-Unit Combinations Rated11

Refrigerant

SpecTempstarYork
TypeR-454BR-410A
GWP RatingR-454B (GWP:470 | Lower GWP)R-410A (GWP:2088)