SpecDirectory

Trane 5TWX6042A1vsYork YH2F42TB21

Side-by-side heat pump comparison

Trane 5TWX6042A1

SEER2

15.2–16BTU/Wh

HSPF2

7.8–8.1BTU/Wh

Cooling Capacity

38500–41500BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

York YH2F42TB21

SEER2

15.2–16BTU/Wh

HSPF2

7.8–8.1BTU/Wh

Cooling Capacity

39500–42000BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

Key differences

The York YH2F42TB21 is larger at 42000 BTU/hr versus 41500 BTU/hr. Trane 5TWX6042A1 uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088).

Efficiency

SpecTraneYork
SEER2 (best combination)(BTU/Wh)1616
SEER2 (worst combination)(BTU/Wh)15.215.2
HSPF2 (best combination)(BTU/Wh)8.18.1
HSPF2 (worst combination)(BTU/Wh)7.87.8
EER2 (best combination)(BTU/Wh)1212
COP at 5 °F2.302.42

Capacity

SpecTraneYork
Cooling Capacity (max)(BTU/hr)4150042000
Cooling Capacity (min)(BTU/hr)3850039500
Heating at 47 °F(BTU/hr)4050041000
Heating at 17 °F(BTU/hr)2600026600
Heating at 5 °F(BTU/hr)1980022600

Configuration

SpecTraneYork
Product TypeHP - Split SystemHP - Split System
Compressor StagingSingle stageTwo-stage
Cold Climate CertifiedNoNo
Connected CapabilityNoNo
Series16 Single-Stage Heat Pump with WeatherGuard TopLX SERIES
Indoor-Unit Combinations Rated187449

Refrigerant

SpecTraneYork
TypeR-454BR-410A
GWP RatingR-454B (GWP:470 | Lower GWP)R-410A (GWP:2088)

More comparisons