Understanding SEER2 Ratings for Heat Pumps
If you are shopping for a heat pump or air conditioner in 2026, every unit you look at carries a SEER2 rating instead of the old SEER number. The switch happened on January 1, 2023, and the new numbers are not directly comparable to the old ones. This guide explains what changed, what the numbers mean, and how to use them.
What SEER2 measures
SEER2 stands for Seasonal Energy Efficiency Ratio 2. Like the original SEER, it measures how much cooling a system delivers per unit of electricity over a typical cooling season. A higher number means less electricity for the same amount of cooling.
The difference is in the test. SEER2 uses the M1 test procedure, which adds external static pressure — essentially, it simulates the resistance of real ductwork. The old SEER test assumed nearly zero duct resistance, which flatters equipment performance. SEER2 numbers are typically 4–5% lower than SEER numbers for the same physical equipment, because the test is harder.
Do not compare a SEER2 rating to an old SEER rating. A unit rated 15 SEER2 is roughly equivalent to a unit that would have been rated 15.7–16.0 SEER under the old test. Comparing them directly will make the new unit look worse than it is.
The federal minimum
As of January 1, 2023, the national minimum for split-system heat pumps is14.3 SEER2 (with a companion heating efficiency of 7.5 HSPF2). This replaced the old 14 SEER minimum.
Regional requirements differ. The Department of Energy divides the country into northern and southern regions, with the South requiring higher efficiency minimums for some equipment types. Always check the current DOE standards for your installation region.
What the numbers mean in practice
A rough rule of thumb: each additional SEER2 point reduces cooling energy use by about 5–7%. Moving from a 14.3 SEER2 unit to a 20 SEER2 unit cuts cooling costs by roughly 30%.
Whether that savings justifies the higher purchase price depends on your climate, your electricity rate, and how many hours per year the system runs in cooling mode. In a hot, humid climate with high electricity rates (the Gulf Coast, the desert Southwest), the payback period is short — often 3–5 years. In a mild climate where cooling runs 600 hours a year, it may take 8–10 years.
SEER2 is only half the story for heat pumps
Heat pumps heat and cool. SEER2 only measures cooling efficiency. For heating efficiency, look at HSPF2 (Heating Seasonal Performance Factor 2). Like SEER2, it replaced the old HSPF rating with a harder test procedure, and the numbers are not directly comparable.
If you live in a heating-dominated climate, HSPF2 matters more than SEER2 for your total energy bill. A unit with exceptional SEER2 but mediocre HSPF2 will save you money in summer and cost you money in winter.
Companion ratings you will see
- EER2 (Energy Efficiency Ratio 2)
- Measures efficiency at a single high outdoor temperature (95°F) rather than across a season. Useful for comparing performance in peak heat. A high EER2 means the unit handles the hottest days well.
- HSPF2 (Heating Seasonal Performance Factor 2)
- The heating-season counterpart to SEER2. Higher is better. The federal minimum for split-system heat pumps is 7.5 HSPF2.
- COP (Coefficient of Performance)
- Used for geothermal heat pumps rather than SEER2. A COP of 4.0 means the system delivers 4 units of heating for every 1 unit of electricity.
Variable-speed, two-stage, and single-stage
SEER2 is a seasonal average, which means it rewards systems that modulate output. Variable-speed compressors run at partial capacity most of the time, which is more efficient than cycling on and off at full blast. That is why the highest SEER2 ratings (20+) are almost exclusively variable-speed units.
Two-stage units offer a middle ground: a low stage for mild days and full capacity for peak demand. Single-stage units are the simplest and least expensive, but also the least efficient at part-load conditions.
Tax credits and incentives
The federal government and many utilities offer incentives for high-efficiency heat pumps. The requirements change, so check the current ENERGY STAR and IRS guidelines before purchasing. As a general rule, the highest incentives go to units meeting ENERGY STAR Most Efficient criteria, which requires performance well above the federal minimum.
Compare heat pumps on SpecDirectory
Browse all 12,218 certified air-source heat pumps from 270 brands on the heat pumps page, ranked by efficiency. Every model page shows SEER2, EER2, HSPF2, and whether the model meets ENERGY STAR Most Efficient criteria.
For gas heating comparisons, see our 2,500 certified furnaces, ranked by AFUE.