37MUHAQ60AA3+KSAIC0701230
BRYANT HEATING AND COOLING SYSTEMS · HP - Split System
15.2–16BTU/Wh
9BTU/Wh
55500–56500BTU/hr
Yes
BRYANT HEATING AND COOLING SYSTEMS 37MUHAQ60AA3+KSAIC0701230: SEER2 16 BTU/Wh, lower than 85% of air-source heat pumps (category median 20 BTU/Wh).
Where this model sits
Lower than 85% of air-source heat pumps.
The BRYANT HEATING AND COOLING SYSTEMS 37MUHAQ60AA3+KSAIC0701230 is a 56500 BTU/hr hp - split system using R-454B, a refrigerant with moderate global warming potential (GWP 470). At 16 BTU/Wh it ranks in the bottom 14% of the 12,218 certified air-source heat pumps models. Among similar-sized air-source heat pumps (within 10% of its size), it is less efficient than the peer median of 17 BTU/Wh. Comparable models from Midea in this size range average 17.8 BTU/Wh.
Specifications
| Efficiency | |
|---|---|
| SEER2 (best combination) | 16BTU/Wh |
| SEER2 (worst combination) | 15.2BTU/Wh |
| HSPF2 (best combination) | 9BTU/Wh |
| HSPF2 (worst combination) | 9BTU/Wh |
| EER2 (best combination) | 9.8BTU/Wh |
| COP at 5 °F | 1.78 |
| Capacity | |
| Cooling Capacity (max) | 56500BTU/hr |
| Cooling Capacity (min) | 55500BTU/hr |
| Heating at 47 °F | 56500BTU/hr |
| Heating at 17 °F | 41000BTU/hr |
| Heating at 5 °F | 51500BTU/hr |
All 25 specifications
| Configuration | |
|---|---|
| Product Type | HP - Split System |
| Compressor Staging | Continuously variable |
| Cold Climate Certified | Yes |
| Connected Capability | No |
| Series | Crossover Heat Pump |
| Indoor-Unit Combinations Rated | 4 |
| Refrigerant | |
| Type | R-454B |
| GWP Rating | R-454B (GWP:470 | Lower GWP) |
| Identifiers | |
| Model Number | 37MUHAQ60AA3+KSAIC0701230 |
| ENERGY STAR ID | ES_1020846_37MUHAQ60AA3+KSAIC0701230_06052026150124_28218478628 |
| Partner | Carrier Corporation |
| Date Certified | 2026-06-16 |
| Available From | 2024-06-27 |
| Markets | United States, Canada |