SpecDirectory

GH5SAN531**AA*

BRYANT HEATING AND COOLING SYSTEMS · HP - Split System

ENERGY STAR CertifiedAir-Source Heat Pumps →
SEER2

15.2–16BTU/Wh

HSPF2

7.8–8BTU/Wh

Cooling Capacity

27400–29400BTU/hr

Refrigerant

R-454B

GWP 470 · Lower
Low SEER2

BRYANT HEATING AND COOLING SYSTEMS GH5SAN531**AA*: SEER2 16 BTU/Wh, lower than 85% of air-source heat pumps (category median 20 BTU/Wh).

SEER2: worse than 87% of the 1132 comparable models within 10% of this capacity. Their median is 20.2 BTU/Wh.

Where this model sits

Cooling29400BTU/hr
6000median 2400060000
SEER216BTU/Wh
15.2median 2035.1

Lower than 85% of air-source heat pumps.

The BRYANT HEATING AND COOLING SYSTEMS GH5SAN531**AA* is a 29400 BTU/hr hp - split system using R-454B, a refrigerant with moderate global warming potential (GWP 470). At 16 BTU/Wh it ranks in the bottom 14% of the 12,218 certified air-source heat pumps models. Among similar-sized air-source heat pumps (within 10% of its size), it is less efficient than the peer median of 20.2 BTU/Wh. In this size range, comparable Midea models average 21 BTU/Wh and MDV models average 22.5 BTU/Wh.

Specifications

Efficiency
SEER2 (best combination)16BTU/Wh
SEER2 (worst combination)15.2BTU/Wh
HSPF2 (best combination)8BTU/Wh
HSPF2 (worst combination)7.8BTU/Wh
EER2 (best combination)13BTU/Wh
COP at 5 °F2.06
Capacity
Cooling Capacity (max)29400BTU/hr
Cooling Capacity (min)27400BTU/hr
Heating at 47 °F30600BTU/hr
Heating at 17 °F18200BTU/hr
Heating at 5 °F14000BTU/hr
All 25 specifications
Configuration
Product TypeHP - Split System
Compressor StagingSingle stage
Cold Climate CertifiedNo
Connected CapabilityNo
Series15 SEER2 HP
Indoor-Unit Combinations Rated41
Refrigerant
TypeR-454B
GWP RatingR-454B (GWP:470 | Lower GWP)
Identifiers
Model NumberGH5SAN531**AA*
ENERGY STAR IDES_1020846_GH5SAN531**AA*_08232025013914_28217683628
PartnerCarrier Corporation
Date Certified2026-06-29
Available From2025-07-31
MarketsUnited States, Canada

Documentation

We link to manufacturer documentation at its original source rather than rehosting it, so you always get the current revision.