SpecDirectory

ASH112PRDWA

GE Appliances · HP - Mini or Multi Split

ENERGY STAR CertifiedAir-Source Heat Pumps →
SEER2

23BTU/Wh

HSPF2

10.2BTU/Wh

Cooling Capacity

12000BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher
GWP 2088 · high impact

GE Appliances ASH112PRDWA: SEER2 23 BTU/Wh, around the middle of the range for air-source heat pumps (category median 20 BTU/Wh).

Where this model sits

Cooling12000BTU/hr
6000median 2400060000
SEER223BTU/Wh
15.2median 2035.1

The GE Appliances ASH112PRDWA is a 12000 BTU/hr hp - mini or multi split using R-410A, a refrigerant with high global warming potential (GWP 2088). At 23 BTU/Wh it ranks around the middle of the 12,218 certified air-source heat pumps models. Among similar-sized air-source heat pumps (within 10% of its size), it is less efficient than the peer median of 23.5 BTU/Wh. In this size range, comparable GREE models average 24.3 BTU/Wh and Hisense models average 23 BTU/Wh.

Specifications

Efficiency
SEER2 (best combination)23BTU/Wh
SEER2 (worst combination)23BTU/Wh
HSPF2 (best combination)10.2BTU/Wh
HSPF2 (worst combination)10.2BTU/Wh
EER2 (best combination)12.5BTU/Wh
COP at 5 °F1.80
Capacity
Cooling Capacity (max)12000BTU/hr
Cooling Capacity (min)12000BTU/hr
Heating at 47 °F12000BTU/hr
Heating at 17 °F10700BTU/hr
Heating at 5 °F8600BTU/hr
All 25 specifications
Configuration
Product TypeHP - Mini or Multi Split
Compressor StagingContinuously variable
Cold Climate CertifiedNo
Connected CapabilityNo
SeriesAltitude
Indoor-Unit Combinations Rated1
Refrigerant
TypeR-410A
GWP RatingR-410A (GWP:2088)
Identifiers
Model NumberASH112PRDWA
ENERGY STAR IDES_1123206_ASH112PRDWA_03142023122035_5354440
PartnerGE Appliances, a Haier Company
Date Certified2026-05-28
Available From2019-01-25
MarketsUnited States, Canada