SpecDirectory

MUZ-FX12NLHZ***

Mitsubishi Electric · HP - Mini or Multi Split

ENERGY STAR CertifiedAir-Source Heat Pumps →
SEER2

29.9BTU/Wh

HSPF2

12.4BTU/Wh

Cooling Capacity

12000BTU/hr

Cold Climate

Yes

Cold climate certified
High SEER2ENERGY STAR Most Efficient

Mitsubishi Electric MUZ-FX12NLHZ***: SEER2 29.9 BTU/Wh, better than 99% of air-source heat pumps (category median 20 BTU/Wh).

SEER2: better than 99% of the 1144 comparable models within 10% of this capacity. Their median is 23.5 BTU/Wh.

Where this model sits

Cooling12000BTU/hr
6000median 2400060000
SEER229.9BTU/Wh
15.2median 2035.1

Better than 99% of air-source heat pumps.

The Mitsubishi Electric MUZ-FX12NLHZ*** is a 12000 BTU/hr hp - mini or multi split using R-454B, a refrigerant with moderate global warming potential (GWP 470). At 29.9 BTU/Wh it ranks better than 99% of the 12,218 certified air-source heat pumps models. Among similar-sized air-source heat pumps (within 10% of its size), it is more efficient than the peer median of 23.5 BTU/Wh. In this size range, comparable GREE models average 24.3 BTU/Wh and Hisense models average 23 BTU/Wh.

Specifications

Efficiency
SEER2 (best combination)29.9BTU/Wh
SEER2 (worst combination)29.9BTU/Wh
HSPF2 (best combination)12.4BTU/Wh
HSPF2 (worst combination)12.4BTU/Wh
EER2 (best combination)15.4BTU/Wh
COP at 5 °F2.20
Capacity
Cooling Capacity (max)12000BTU/hr
Cooling Capacity (min)12000BTU/hr
Heating at 47 °F13200BTU/hr
Heating at 17 °F9300BTU/hr
Heating at 5 °F16200BTU/hr
All 25 specifications
Configuration
Product TypeHP - Mini or Multi Split
Compressor StagingContinuously variable
Cold Climate CertifiedYes
Connected CapabilityNo
SeriesM-Series
Indoor-Unit Combinations Rated1
Refrigerant
TypeR-454B
GWP RatingR-454B (GWP:470 | Lower GWP)
Identifiers
Model NumberMUZ-FX12NLHZ***
ENERGY STAR IDES_14817_MUZ-FX12NLHZ***_09172024013051_1647857
PartnerMitsubishi Electric U.S. HVAC Division
Date Certified2025-02-17
Available From2025-01-01
MarketsUnited States, Canada

Documentation

We link to manufacturer documentation at its original source rather than rehosting it, so you always get the current revision.