SpecDirectory

CENTRAL-18-HP-C-23025

MRCOOL · HP - Split System

ENERGY STAR CertifiedAir-Source Heat Pumps →
SEER2

16.6BTU/Wh

HSPF2

10.2BTU/Wh

Cooling Capacity

17000BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher
GWP 2088 · high impact

MRCOOL CENTRAL-18-HP-C-23025: SEER2 16.6 BTU/Wh, around the middle of the range for air-source heat pumps (category median 20 BTU/Wh).

SEER2: worse than 90% of the 1611 comparable models within 10% of this capacity. Their median is 21 BTU/Wh.

Where this model sits

Cooling17000BTU/hr
6000median 2400060000
SEER216.6BTU/Wh
15.2median 2035.1

The MRCOOL CENTRAL-18-HP-C-23025 is a 17000 BTU/hr hp - split system using R-410A, a refrigerant with high global warming potential (GWP 2088). At 16.6 BTU/Wh it ranks around the middle of the 12,218 certified air-source heat pumps models. Among similar-sized air-source heat pumps (within 10% of its size), it is less efficient than the peer median of 21 BTU/Wh. In this size range, comparable Midea models average 20.6 BTU/Wh and TOSOT models average 21 BTU/Wh.

Specifications

Efficiency
SEER2 (best combination)16.6BTU/Wh
SEER2 (worst combination)16.6BTU/Wh
HSPF2 (best combination)10.2BTU/Wh
HSPF2 (worst combination)10.2BTU/Wh
EER2 (best combination)11.7BTU/Wh
Capacity
Cooling Capacity (max)17000BTU/hr
Cooling Capacity (min)17000BTU/hr
Heating at 47 °F18000BTU/hr
Heating at 17 °F14800BTU/hr
All 23 specifications
Configuration
Product TypeHP - Split System
Compressor StagingContinuously variable
Cold Climate CertifiedNo
Connected CapabilityNo
SeriesCENTRAL
Indoor-Unit Combinations Rated1
Refrigerant
TypeR-410A
GWP RatingR-410A (GWP:2088)
Identifiers
Model NumberCENTRAL-18-HP-C-23025
ENERGY STAR IDES_1132632_CENTRAL-18-HP-C-23025_02212023200954_5379040
PartnerHVAC Distributing, LLC.
Date Certified2025-02-17
Available From2022-07-01
MarketsUnited States, Canada

Documentation

We link to manufacturer documentation at its original source rather than rehosting it, so you always get the current revision.