SpecDirectory

RD18AY60AJVC

Rheem · HP - Split System

ENERGY STAR CertifiedAir-Source Heat Pumps →
SEER2

16–18BTU/Wh

HSPF2

8.1–10BTU/Wh

Cooling Capacity

48500–52000BTU/hr

Cold Climate

Yes

Cold climate certified

Rheem RD18AY60AJVC: SEER2 18 BTU/Wh, around the middle of the range for air-source heat pumps (category median 20 BTU/Wh).

Where this model sits

Cooling52000BTU/hr
6000median 2400060000
SEER218BTU/Wh
15.2median 2035.1

The Rheem RD18AY60AJVC is a 52000 BTU/hr hp - split system using R-454B, a refrigerant with moderate global warming potential (GWP 470). At 18 BTU/Wh it ranks around the middle of the 12,218 certified air-source heat pumps models. Among similar-sized air-source heat pumps (within 10% of its size), it is about as efficient as the peer median of 17.5 BTU/Wh. In this size range, comparable Midea models average 18.7 BTU/Wh and Carrier models average 16 BTU/Wh.

Specifications

Efficiency
SEER2 (best combination)18BTU/Wh
SEER2 (worst combination)16BTU/Wh
HSPF2 (best combination)10BTU/Wh
HSPF2 (worst combination)8.1BTU/Wh
EER2 (best combination)11.7BTU/Wh
COP at 5 °F2.10
Capacity
Cooling Capacity (max)52000BTU/hr
Cooling Capacity (min)48500BTU/hr
Heating at 47 °F60000BTU/hr
Heating at 17 °F42500BTU/hr
Heating at 5 °F39500BTU/hr
All 25 specifications
Configuration
Product TypeHP - Split System
Compressor StagingContinuously variable
Cold Climate CertifiedYes
Connected CapabilityYes
SeriesPRESTIGE SERIES
Indoor-Unit Combinations Rated61
Refrigerant
TypeR-454B
GWP RatingR-454B (GWP:470 | Lower GWP)
Identifiers
Model NumberRD18AY60AJVC
ENERGY STAR IDES_1071043_RD18AY60AJVC_12152024013004_20216613161
PartnerRheem Sales Company, Inc.
Date Certified2026-02-11
Available From2024-12-14
MarketsUnited States, Canada

Documentation

We link to manufacturer documentation at its original source rather than rehosting it, so you always get the current revision.