SpecDirectory

TMH36HEI2NAS0U25*

TCL · HP - Mini or Multi Split

ENERGY STAR CertifiedAir-Source Heat Pumps →
SEER2

20–25BTU/Wh

HSPF2

9–10BTU/Wh

Cooling Capacity

36000BTU/hr

Cold Climate

Yes

Cold climate certified
High SEER2ENERGY STAR Most Efficient

TCL TMH36HEI2NAS0U25*: SEER2 25 BTU/Wh, better than 89% of air-source heat pumps (category median 20 BTU/Wh).

SEER2: better than 99% of the 1795 comparable models within 10% of this capacity. Their median is 19 BTU/Wh.

Where this model sits

Cooling36000BTU/hr
6000median 2400060000
SEER225BTU/Wh
15.2median 2035.1

Better than 89% of air-source heat pumps.

The TCL TMH36HEI2NAS0U25* is a 36000 BTU/hr hp - mini or multi split using R-454B, a refrigerant with moderate global warming potential (GWP 470). At 25 BTU/Wh it ranks better than 89% of the 12,218 certified air-source heat pumps models. Among similar-sized air-source heat pumps (within 10% of its size), it is more efficient than the peer median of 19 BTU/Wh. In this size range, comparable Midea models average 20 BTU/Wh and TOSOT models average 21 BTU/Wh.

Specifications

Efficiency
SEER2 (best combination)25BTU/Wh
SEER2 (worst combination)20BTU/Wh
HSPF2 (best combination)10BTU/Wh
HSPF2 (worst combination)9BTU/Wh
EER2 (best combination)13.6BTU/Wh
COP at 5 °F2
Capacity
Cooling Capacity (max)36000BTU/hr
Cooling Capacity (min)36000BTU/hr
Heating at 47 °F36000BTU/hr
Heating at 17 °F36800BTU/hr
Heating at 5 °F33000BTU/hr
All 25 specifications
Configuration
Product TypeHP - Mini or Multi Split
Compressor StagingContinuously variable
Cold Climate CertifiedYes
Connected CapabilityNo
Seriesfree match 27S HT
Indoor-Unit Combinations Rated3
Refrigerant
TypeR-454B
GWP RatingR-454B (GWP:470 | Lower GWP)
Identifiers
Model NumberTMH36HEI2NAS0U25*
ENERGY STAR IDES_1126578_TMH36HEI2NAS0U25*_06182026040000_29218625173
PartnerTCL Air conditioner (Zhong Shan) Co., Ltd.
Date Certified2026-07-17
Available From2026-06-18
MarketsUnited States, Canada

Documentation