5HCL6048A1000A*
Trane/American Standard · HP - Split System
18.1BTU/Wh
8.5BTU/Wh
48000BTU/hr
Yes
Trane/American Standard 5HCL6048A1000A*: SEER2 18.1 BTU/Wh, around the middle of the range for air-source heat pumps (category median 20 BTU/Wh).
Where this model sits
The Trane/American Standard 5HCL6048A1000A* is a 48000 BTU/hr hp - split system using R-454B, a refrigerant with moderate global warming potential (GWP 470). At 18.1 BTU/Wh it ranks around the middle of the 12,218 certified air-source heat pumps models. Among similar-sized air-source heat pumps (within 10% of its size), it is about as efficient as the peer median of 18 BTU/Wh. In this size range, comparable Midea models average 18.8 BTU/Wh and Airquest models average 18.4 BTU/Wh.
Specifications
| Efficiency | |
|---|---|
| SEER2 (best combination) | 18.1BTU/Wh |
| SEER2 (worst combination) | 18.1BTU/Wh |
| HSPF2 (best combination) | 8.5BTU/Wh |
| HSPF2 (worst combination) | 8.5BTU/Wh |
| EER2 (best combination) | 9.4BTU/Wh |
| COP at 5 °F | 1.90 |
| Capacity | |
| Cooling Capacity (max) | 48000BTU/hr |
| Cooling Capacity (min) | 48000BTU/hr |
| Heating at 47 °F | 60000BTU/hr |
| Heating at 17 °F | 52000BTU/hr |
| Heating at 5 °F | 52000BTU/hr |
All 25 specifications
| Configuration | |
|---|---|
| Product Type | HP - Split System |
| Compressor Staging | Continuously variable |
| Cold Climate Certified | Yes |
| Connected Capability | No |
| Series | M series |
| Indoor-Unit Combinations Rated | 1 |
| Refrigerant | |
| Type | R-454B |
| GWP Rating | R-454B (GWP:470 | Lower GWP) |
| Identifiers | |
| Model Number | 5HCL6048A1000A* |
| ENERGY STAR ID | ES_14817_5HCL6048A1000A*_06102025203007_28217497625 |
| Partner | Mitsubishi Electric U.S. HVAC Division |
| Date Certified | 2025-06-27 |
| Available From | 2025-04-01 |
| Markets | United States, Canada |
Documentation
We link to manufacturer documentation at its original source rather than rehosting it, so you always get the current revision.