Follett C1414AvsHoshizaki KM-1340MAJ
Side-by-side ice machine comparison
Follett C1414A
Harvest Rate
1107lb/day
Energy Use
4.53kWh/100 lb
Water Use
12gal/100 lb
Refrigerant
R-290
GWP 3 · Lower
Hoshizaki KM-1340MAJ
Harvest Rate
1175lb/day
Energy Use
4.20kWh/100 lb
Water Use
17gal/100 lb
Refrigerant
R-404A
GWP 3920 · Higher
Key differences
Hoshizaki KM-1340MAJ is 7% more efficient at 4.20 kWh/100 lb versus 4.53 kWh/100 lb for the Follett C1414A. The Hoshizaki KM-1340MAJ is larger at 1175 lb/day versus 1107 lb/day. Follett C1414A uses a lower-impact refrigerant: R-290 (GWP 3) versus R-404A (GWP 3920).
Production
| Spec | Follett | Hoshizaki |
|---|---|---|
| Harvest Rate(lb/day) | 1107 | 1175 |
| Ice Type | Continuous | Batch |
| Equipment Type | Ice Making Head | Ice Making Head |
| Ice Hardness Factor | 89.70 | 100 |
Efficiency
| Spec | Follett | Hoshizaki |
|---|---|---|
| Energy Use(kWh/100 lb) | 4.53 | 4.20 |
| Potable Water Use(gal/100 lb) | 12 | 17 |
Refrigerant
| Spec | Follett | Hoshizaki |
|---|---|---|
| Type | R-290 | R-404A |
| GWP Rating | R-290 (GWP:3 | Lower GWP) | R-404A (GWP:3920) |
Connectivity
| Spec | Follett | Hoshizaki |
|---|---|---|
| Connected | No | No |