SpecDirectory

1HVAC SC-27Z-HH-M4BvsAUX ASW-H24F8A2/**R3DI-C7

Side-by-side heat pump comparison

1HVAC SC-27Z-HH-M4B

SEER2

21BTU/Wh

HSPF2

10BTU/Wh

Cooling Capacity

23200BTU/hr

Cold Climate

Yes

Cold climate certified

AUX ASW-H24F8A2/**R3DI-C7

SEER2

22BTU/Wh

HSPF2

10BTU/Wh

Cooling Capacity

23000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

AUX ASW-H24F8A2/**R3DI-C7 is 5% more efficient at 22.0 BTU/Wh versus 21.0 BTU/Wh for the 1HVAC SC-27Z-HH-M4B. The 1HVAC SC-27Z-HH-M4B is larger at 23200 BTU/hr versus 23000 BTU/hr. AUX ASW-H24F8A2/**R3DI-C7 uses a lower-impact refrigerant: R-32 (GWP 675) versus R-410A (GWP 2088).

Efficiency

Spec1HVACAUX
SEER2 (best combination)(BTU/Wh)2122
SEER2 (worst combination)(BTU/Wh)2122
HSPF2 (best combination)(BTU/Wh)1010
HSPF2 (worst combination)(BTU/Wh)1010
EER2 (best combination)(BTU/Wh)12.512
COP at 5 °F2.102.20

Capacity

Spec1HVACAUX
Cooling Capacity (max)(BTU/hr)2320023000
Cooling Capacity (min)(BTU/hr)2320023000
Heating at 47 °F(BTU/hr)2400024000
Heating at 17 °F(BTU/hr)2360022400
Heating at 5 °F(BTU/hr)2160020800

Configuration

Spec1HVACAUX
Product TypeHP - Mini or Multi SplitHP - Mini or Multi Split
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesExtreme HeatM-Series
Indoor-Unit Combinations Rated11

Refrigerant

Spec1HVACAUX
TypeR-410AR-32
GWP RatingR-410A (GWP:2088)R-32 (GWP:675 | Lower GWP)