SpecDirectory

AC PRO AK-H04TC/NAA-T(U)vsACIQ N5H5S48*K*AAA*

Side-by-side heat pump comparison

AC PRO AK-H04TC/NAA-T(U)

SEER2

17.8BTU/Wh

HSPF2

8.5BTU/Wh

Cooling Capacity

47000BTU/hr

Cold Climate

Yes

Cold climate certified

ACIQ N5H5S48*K*AAA*

SEER2

15.2–15.5BTU/Wh

HSPF2

7.8BTU/Wh

Cooling Capacity

46500–47500BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

Key differences

AC PRO AK-H04TC/NAA-T(U) is 13% more efficient at 17.8 BTU/Wh versus 15.5 BTU/Wh for the ACIQ N5H5S48*K*AAA*. The ACIQ N5H5S48*K*AAA* is larger at 47500 BTU/hr versus 47000 BTU/hr. ACIQ N5H5S48*K*AAA* uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088). Overall, the AC PRO AK-H04TC/NAA-T(U) sits higher in the category, ranking above 83% of certified air-source heat pumps.

Efficiency

SpecAC PROACIQ
SEER2 (best combination)(BTU/Wh)17.815.5
SEER2 (worst combination)(BTU/Wh)17.815.2
HSPF2 (best combination)(BTU/Wh)8.57.8
HSPF2 (worst combination)(BTU/Wh)8.57.8
EER2 (best combination)(BTU/Wh)1112.5
COP at 5 °F1.802.30

Capacity

SpecAC PROACIQ
Cooling Capacity (max)(BTU/hr)4700047500
Cooling Capacity (min)(BTU/hr)4700046500
Heating at 47 °F(BTU/hr)4700047500
Heating at 17 °F(BTU/hr)3600030600
Heating at 5 °F(BTU/hr)4600024400

Configuration

SpecAC PROACIQ
Product TypeHP - Single PackageHP - Split System
Compressor StagingContinuously variableSingle stage
Cold Climate CertifiedYesNo
Connected CapabilityNoNo
SeriesX SeriesPERFORMANCE 16 SEER2 HP
Indoor-Unit Combinations Rated13

Refrigerant

SpecAC PROACIQ
TypeR-410AR-454B
GWP RatingR-410A (GWP:2088)R-454B (GWP:470 | Lower GWP)

More comparisons