SpecDirectory

ACIQ B5H0V24*K*AAA*vsComfortmaker DLCURAH24AAK

Side-by-side heat pump comparison

ACIQ B5H0V24*K*AAA*

SEER2

15.5–17.5BTU/Wh

HSPF2

8.5–9BTU/Wh

Cooling Capacity

22400–24200BTU/hr

Cold Climate

Yes

Cold climate certified

Comfortmaker DLCURAH24AAK

SEER2

16.3–17BTU/Wh

HSPF2

9.2–9.8BTU/Wh

Cooling Capacity

24000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

ACIQ B5H0V24*K*AAA* is 3% more efficient at 17.5 BTU/Wh versus 17.0 BTU/Wh for the Comfortmaker DLCURAH24AAK. The ACIQ B5H0V24*K*AAA* is larger at 24200 BTU/hr versus 24000 BTU/hr. ACIQ B5H0V24*K*AAA* uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088).

Efficiency

SpecACIQComfortmaker
SEER2 (best combination)(BTU/Wh)17.517
SEER2 (worst combination)(BTU/Wh)15.516.3
HSPF2 (best combination)(BTU/Wh)99.8
HSPF2 (worst combination)(BTU/Wh)8.59.2
EER2 (best combination)(BTU/Wh)10.511.1
COP at 5 °F2.022.10

Capacity

SpecACIQComfortmaker
Cooling Capacity (max)(BTU/hr)2420024000
Cooling Capacity (min)(BTU/hr)2240024000
Heating at 47 °F(BTU/hr)2460026000
Heating at 17 °F(BTU/hr)2080021000
Heating at 5 °F(BTU/hr)1730020800

Configuration

SpecACIQComfortmaker
Product TypeHP - Split SystemHP - Split System
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesDeluxe 20 VS Heat PumpDlseries
Indoor-Unit Combinations Rated863

Refrigerant

SpecACIQComfortmaker
TypeR-454BR-410A
GWP RatingR-454B (GWP:470 | Lower GWP)R-410A (GWP:2088)

More comparisons