ACIQ B5H0V24*K*AAA*

SEER2

15.5–17.5BTU/Wh

HSPF2

8.5–9BTU/Wh

Cooling Capacity

22400–24200BTU/hr

Cold Climate

Yes

Cold climate certified

MDV MOX430U-24HFN1-MR0

SEER2

15.7–18.4BTU/Wh

HSPF2

9.2–10.2BTU/Wh

Cooling Capacity

18200–24000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

MDV MOX430U-24HFN1-MR0 is 5% more efficient at 18.4 BTU/Wh versus 17.5 BTU/Wh for the ACIQ B5H0V24*K*AAA*. The ACIQ B5H0V24*K*AAA* is larger at 24200 BTU/hr versus 24000 BTU/hr. ACIQ B5H0V24*K*AAA* uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088).

Efficiency

SpecACIQMDV
SEER2 (best combination)(BTU/Wh)17.518.4
SEER2 (worst combination)(BTU/Wh)15.515.7
HSPF2 (best combination)(BTU/Wh)910.2
HSPF2 (worst combination)(BTU/Wh)8.59.2
EER2 (best combination)(BTU/Wh)10.512.5
COP at 5 °F2.022.33

Capacity

SpecACIQMDV
Cooling Capacity (max)(BTU/hr)2420024000
Cooling Capacity (min)(BTU/hr)2240018200
Heating at 47 °F(BTU/hr)2460026000
Heating at 17 °F(BTU/hr)2080022000
Heating at 5 °F(BTU/hr)1730020800

Configuration

SpecACIQMDV
Product TypeHP - Split SystemHP - Split System
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesDeluxe 20 VS Heat PumpMVC SERIES
Indoor-Unit Combinations Rated865

Refrigerant

SpecACIQMDV
TypeR-454BR-410A
GWP RatingR-454B (GWP:470 | Lower GWP)R-410A (GWP:2088)