ACIQ B5H0V24*K*AAA*

SEER2

15.5–17.5BTU/Wh

HSPF2

8.5–9BTU/Wh

Cooling Capacity

22400–24200BTU/hr

Cold Climate

Yes

Cold climate certified

Senville SENE-24EL-OH

SEER2

25BTU/Wh

HSPF2

11BTU/Wh

Cooling Capacity

24000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Senville SENE-24EL-OH is 30% more efficient at 25.0 BTU/Wh versus 17.5 BTU/Wh for the ACIQ B5H0V24*K*AAA*. The ACIQ B5H0V24*K*AAA* is larger at 24200 BTU/hr versus 24000 BTU/hr. Overall, the Senville SENE-24EL-OH sits higher in the category, ranking above 89% of certified air-source heat pumps.

Efficiency

SpecACIQSenville
SEER2 (best combination)(BTU/Wh)17.525
SEER2 (worst combination)(BTU/Wh)15.525
HSPF2 (best combination)(BTU/Wh)911
HSPF2 (worst combination)(BTU/Wh)8.511
EER2 (best combination)(BTU/Wh)10.514
COP at 5 °F2.022.20

Capacity

SpecACIQSenville
Cooling Capacity (max)(BTU/hr)2420024000
Cooling Capacity (min)(BTU/hr)2240024000
Heating at 47 °F(BTU/hr)2460024000
Heating at 17 °F(BTU/hr)2080017100
Heating at 5 °F(BTU/hr)1730020000

Configuration

SpecACIQSenville
Product TypeHP - Split SystemHP - Mini or Multi Split
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesDeluxe 20 VS Heat PumpSENE Series
Indoor-Unit Combinations Rated861

Refrigerant

SpecACIQSenville
TypeR-454BR-454B
GWP RatingR-454B (GWP:470 | Lower GWP)R-454B (GWP:470 | Lower GWP)