SpecDirectory

ACIQ N5H5S36*K*AAA*vsBryant 37MBHAQ36AA3

Side-by-side heat pump comparison

ACIQ N5H5S36*K*AAA*

SEER2

15.2–15.5BTU/Wh

HSPF2

7.8–8BTU/Wh

Cooling Capacity

33800–36800BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

Bryant 37MBHAQ36AA3

SEER2

17.3–21.3BTU/Wh

HSPF2

9.5–11.1BTU/Wh

Cooling Capacity

36000–36600BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Bryant 37MBHAQ36AA3 is 27% more efficient at 21.3 BTU/Wh versus 15.5 BTU/Wh for the ACIQ N5H5S36*K*AAA*. The ACIQ N5H5S36*K*AAA* is larger at 36800 BTU/hr versus 36600 BTU/hr. Overall, the Bryant 37MBHAQ36AA3 sits higher in the category, ranking above 77% of certified air-source heat pumps.

Efficiency

SpecACIQBryant
SEER2 (best combination)(BTU/Wh)15.521.3
SEER2 (worst combination)(BTU/Wh)15.217.3
HSPF2 (best combination)(BTU/Wh)811.1
HSPF2 (worst combination)(BTU/Wh)7.89.5
EER2 (best combination)(BTU/Wh)1312
COP at 5 °F2.202.10

Capacity

SpecACIQBryant
Cooling Capacity (max)(BTU/hr)3680036600
Cooling Capacity (min)(BTU/hr)3380036000
Heating at 47 °F(BTU/hr)3620042000
Heating at 17 °F(BTU/hr)2280031600
Heating at 5 °F(BTU/hr)1810039500

Configuration

SpecACIQBryant
Product TypeHP - Split SystemHP - Split System
Compressor StagingSingle stageContinuously variable
Cold Climate CertifiedNoYes
Connected CapabilityNoNo
SeriesPERFORMANCE 16 SEER2 HP45M Series
Indoor-Unit Combinations Rated264

Refrigerant

SpecACIQBryant
TypeR-454BR-454B
GWP RatingR-454B (GWP:470 | Lower GWP)R-454B (GWP:470 | Lower GWP)