SpecDirectory

ACIQ N5H5S36*K*AAA*vsFraser-Johnston PHG6B361002X4

Side-by-side heat pump comparison

ACIQ N5H5S36*K*AAA*

SEER2

15.2–15.5BTU/Wh

HSPF2

7.8–8BTU/Wh

Cooling Capacity

33800–36800BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

Fraser-Johnston PHG6B361002X4

SEER2

15.2BTU/Wh

HSPF2

7.2BTU/Wh

Cooling Capacity

36600BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

Key differences

Both models are closely matched on seer2: 15.5 vs 15.2 BTU/Wh. The ACIQ N5H5S36*K*AAA* is larger at 36800 BTU/hr versus 36600 BTU/hr. ACIQ N5H5S36*K*AAA* uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088). Overall, the ACIQ N5H5S36*K*AAA* sits higher in the category, ranking above 10% of certified air-source heat pumps.

Efficiency

SpecACIQFraser-Johnston
SEER2 (best combination)(BTU/Wh)15.515.2
SEER2 (worst combination)(BTU/Wh)15.215.2
HSPF2 (best combination)(BTU/Wh)87.2
HSPF2 (worst combination)(BTU/Wh)7.87.2
EER2 (best combination)(BTU/Wh)1312
COP at 5 °F2.202.14

Capacity

SpecACIQFraser-Johnston
Cooling Capacity (max)(BTU/hr)3680036600
Cooling Capacity (min)(BTU/hr)3380036600
Heating at 47 °F(BTU/hr)3620032600
Heating at 17 °F(BTU/hr)2280022000
Heating at 5 °F(BTU/hr)1810030600

Configuration

SpecACIQFraser-Johnston
Product TypeHP - Split SystemHP - Single Package
Compressor StagingSingle stageTwo-stage
Cold Climate CertifiedNoNo
Connected CapabilityNoNo
SeriesPERFORMANCE 16 SEER2 HPLX SERIES
Indoor-Unit Combinations Rated261

Refrigerant

SpecACIQFraser-Johnston
TypeR-454BR-410A
GWP RatingR-454B (GWP:470 | Lower GWP)R-410A (GWP:2088)