SpecDirectory

ACIQ N5H5S48*K*AAA*vsCanAir 4C25MC548H21

Side-by-side heat pump comparison

ACIQ N5H5S48*K*AAA*

SEER2

15.2–15.5BTU/Wh

HSPF2

7.8BTU/Wh

Cooling Capacity

46500–47500BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

CanAir 4C25MC548H21

SEER2

20.4–24BTU/Wh

HSPF2

10.3–10.6BTU/Wh

Cooling Capacity

45000–47000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

CanAir 4C25MC548H21 is 35% more efficient at 24.0 BTU/Wh versus 15.5 BTU/Wh for the ACIQ N5H5S48*K*AAA*. The ACIQ N5H5S48*K*AAA* is larger at 47500 BTU/hr versus 47000 BTU/hr. Overall, the CanAir 4C25MC548H21 sits higher in the category, ranking above 84% of certified air-source heat pumps.

Efficiency

SpecACIQCanAir
SEER2 (best combination)(BTU/Wh)15.524
SEER2 (worst combination)(BTU/Wh)15.220.4
HSPF2 (best combination)(BTU/Wh)7.810.6
HSPF2 (worst combination)(BTU/Wh)7.810.3
EER2 (best combination)(BTU/Wh)12.512.5
COP at 5 °F2.302.10

Capacity

SpecACIQCanAir
Cooling Capacity (max)(BTU/hr)4750047000
Cooling Capacity (min)(BTU/hr)4650045000
Heating at 47 °F(BTU/hr)4750048000
Heating at 17 °F(BTU/hr)3060040000
Heating at 5 °F(BTU/hr)2440038000

Configuration

SpecACIQCanAir
Product TypeHP - Split SystemHP - Mini or Multi Split
Compressor StagingSingle stageContinuously variable
Cold Climate CertifiedNoYes
Connected CapabilityNoNo
SeriesPERFORMANCE 16 SEER2 HP4C Series
Indoor-Unit Combinations Rated33

Refrigerant

SpecACIQCanAir
TypeR-454BR-454B
GWP RatingR-454B (GWP:470 | Lower GWP)R-454B (GWP:470 | Lower GWP)

More comparisons