SpecDirectory

AireForce GXH18(5.3)FMK4DH-1vsAmana AZV6SA1810A*

Side-by-side heat pump comparison

AireForce GXH18(5.3)FMK4DH-1

SEER2

21BTU/Wh

HSPF2

10BTU/Wh

Cooling Capacity

17000BTU/hr

Cold Climate

Yes

Cold climate certified

Amana AZV6SA1810A*

SEER2

16–19BTU/Wh

HSPF2

8.5–8.8BTU/Wh

Cooling Capacity

17000–17100BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

AireForce GXH18(5.3)FMK4DH-1 is 10% more efficient at 21.0 BTU/Wh versus 19.0 BTU/Wh for the Amana AZV6SA1810A*. The Amana AZV6SA1810A* is larger at 17100 BTU/hr versus 17000 BTU/hr. Amana AZV6SA1810A* uses a lower-impact refrigerant: R-32 (GWP 675) versus R-410A (GWP 2088).

Efficiency

SpecAireForceAmana
SEER2 (best combination)(BTU/Wh)2119
SEER2 (worst combination)(BTU/Wh)2116
HSPF2 (best combination)(BTU/Wh)108.8
HSPF2 (worst combination)(BTU/Wh)108.5
EER2 (best combination)(BTU/Wh)1212
COP at 5 °F2.222.10

Capacity

SpecAireForceAmana
Cooling Capacity (max)(BTU/hr)1700017100
Cooling Capacity (min)(BTU/hr)1700017000
Heating at 47 °F(BTU/hr)1800017400
Heating at 17 °F(BTU/hr)1500010800
Heating at 5 °F(BTU/hr)1360013000

Configuration

SpecAireForceAmana
Product TypeHP - Mini or Multi SplitHP - Split System
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoYes
SeriesFlex MatchAZV6SA
Indoor-Unit Combinations Rated173

Refrigerant

SpecAireForceAmana
TypeR-410AR-32
GWP RatingR-410A (GWP:2088)R-32 (GWP:675 | Lower GWP)

More comparisons