Airquest D5CURAH30AAK

SEER2

18.6BTU/Wh

HSPF2

8.7BTU/Wh

Cooling Capacity

30000BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

ALLIED 4SHP17LE130P-**A

SEER2

15.6BTU/Wh

HSPF2

8.1BTU/Wh

Cooling Capacity

29800BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

Key differences

Airquest D5CURAH30AAK is 16% more efficient at 18.6 BTU/Wh versus 15.6 BTU/Wh for the ALLIED 4SHP17LE130P-**A. The Airquest D5CURAH30AAK is larger at 30000 BTU/hr versus 29800 BTU/hr. Airquest D5CURAH30AAK uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088). Overall, the Airquest D5CURAH30AAK sits higher in the category, ranking above 59% of certified air-source heat pumps.

Efficiency

SpecAirquestALLIED
SEER2 (best combination)(BTU/Wh)18.615.6
SEER2 (worst combination)(BTU/Wh)18.615.6
HSPF2 (best combination)(BTU/Wh)8.78.1
HSPF2 (worst combination)(BTU/Wh)8.78.1
EER2 (best combination)(BTU/Wh)1112.5
COP at 5 °F1.992.36

Capacity

SpecAirquestALLIED
Cooling Capacity (max)(BTU/hr)3000029800
Cooling Capacity (min)(BTU/hr)3000029800
Heating at 47 °F(BTU/hr)3100028400
Heating at 17 °F(BTU/hr)1820018800
Heating at 5 °F(BTU/hr)1870014900

Configuration

SpecAirquestALLIED
Product TypeHP - Split SystemHP - Split System
Compressor StagingContinuously variableSingle stage
Cold Climate CertifiedNoNo
Connected CapabilityNoNo
SeriesD5C Series4SHP17 SERIES
Indoor-Unit Combinations Rated11

Refrigerant

SpecAirquestALLIED
TypeR-454BR-410A
GWP RatingR-454B (GWP:470 | Lower GWP)R-410A (GWP:2088)