SpecDirectory

Airquest N5H5S30*K*AAA*vsAUX AHU30HPV1BO

Side-by-side heat pump comparison

Airquest N5H5S30*K*AAA*

SEER2

15.2BTU/Wh

HSPF2

7.8–8.1BTU/Wh

Cooling Capacity

27600–30200BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

AUX AHU30HPV1BO

SEER2

18BTU/Wh

HSPF2

9BTU/Wh

Cooling Capacity

30000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

AUX AHU30HPV1BO is 16% more efficient at 18.0 BTU/Wh versus 15.2 BTU/Wh for the Airquest N5H5S30*K*AAA*. The Airquest N5H5S30*K*AAA* is larger at 30200 BTU/hr versus 30000 BTU/hr. Airquest N5H5S30*K*AAA* uses a lower-impact refrigerant: R-454B (GWP 470) versus R-32 (GWP 675). Overall, the AUX AHU30HPV1BO sits higher in the category, ranking above 59% of certified air-source heat pumps.

Efficiency

SpecAirquestAUX
SEER2 (best combination)(BTU/Wh)15.218
SEER2 (worst combination)(BTU/Wh)15.218
HSPF2 (best combination)(BTU/Wh)8.19
HSPF2 (worst combination)(BTU/Wh)7.89
EER2 (best combination)(BTU/Wh)12.511.6
COP at 5 °F2.261.82

Capacity

SpecAirquestAUX
Cooling Capacity (max)(BTU/hr)3020030000
Cooling Capacity (min)(BTU/hr)2760030000
Heating at 47 °F(BTU/hr)2900033000
Heating at 17 °F(BTU/hr)1780033000
Heating at 5 °F(BTU/hr)1390032200

Configuration

SpecAirquestAUX
Product TypeHP - Split SystemHP - Split System
Compressor StagingSingle stageContinuously variable
Cold Climate CertifiedNoYes
Connected CapabilityNoNo
SeriesPERFORMANCE 16 SEER2 HPB-Series
Indoor-Unit Combinations Rated61

Refrigerant

SpecAirquestAUX
TypeR-454BR-32
GWP RatingR-454B (GWP:470 | Lower GWP)R-32 (GWP:675 | Lower GWP)

More comparisons