SpecDirectory

Airquest N5H5S30*K*AAA*vsTrane / Mitsubishi Electric TRUZA0301HA70**

Side-by-side heat pump comparison

Airquest N5H5S30*K*AAA*

SEER2

15.2BTU/Wh

HSPF2

7.8–8.1BTU/Wh

Cooling Capacity

27600–30200BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

Trane / Mitsubishi Electric TRUZA0301HA70**

SEER2

23.4BTU/Wh

HSPF2

9.5BTU/Wh

Cooling Capacity

30000BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

Key differences

Trane / Mitsubishi Electric TRUZA0301HA70** is 35% more efficient at 23.4 BTU/Wh versus 15.2 BTU/Wh for the Airquest N5H5S30*K*AAA*. The Airquest N5H5S30*K*AAA* is larger at 30200 BTU/hr versus 30000 BTU/hr. Airquest N5H5S30*K*AAA* uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088). Overall, the Trane / Mitsubishi Electric TRUZA0301HA70** sits higher in the category, ranking above 81% of certified air-source heat pumps.

Efficiency

SpecAirquestTrane / Mitsubishi Electric
SEER2 (best combination)(BTU/Wh)15.223.4
SEER2 (worst combination)(BTU/Wh)15.223.4
HSPF2 (best combination)(BTU/Wh)8.19.5
HSPF2 (worst combination)(BTU/Wh)7.89.5
EER2 (best combination)(BTU/Wh)12.511.8
COP at 5 °F2.262.18

Capacity

SpecAirquestTrane / Mitsubishi Electric
Cooling Capacity (max)(BTU/hr)3020030000
Cooling Capacity (min)(BTU/hr)2760030000
Heating at 47 °F(BTU/hr)2900032600
Heating at 17 °F(BTU/hr)1780018100
Heating at 5 °F(BTU/hr)1390012300

Configuration

SpecAirquestTrane / Mitsubishi Electric
Product TypeHP - Split SystemHP - Mini or Multi Split
Compressor StagingSingle stageContinuously variable
Cold Climate CertifiedNoNo
Connected CapabilityNoNo
SeriesPERFORMANCE 16 SEER2 HPP-Series
Indoor-Unit Combinations Rated62

Refrigerant

SpecAirquestTrane / Mitsubishi Electric
TypeR-454BR-410A
GWP RatingR-454B (GWP:470 | Lower GWP)R-410A (GWP:2088)

More comparisons