SpecDirectory

Airquest PHB524000K000B*vsAUX ASW-H24F4D2/**R3DI-C6

Side-by-side heat pump comparison

Airquest PHB524000K000B*

SEER2

15.2BTU/Wh

HSPF2

7.2BTU/Wh

Cooling Capacity

22200BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

AUX ASW-H24F4D2/**R3DI-C6

SEER2

21BTU/Wh

HSPF2

10BTU/Wh

Cooling Capacity

22000BTU/hr

Refrigerant

R-32

GWP 675 · Lower

Key differences

AUX ASW-H24F4D2/**R3DI-C6 is 28% more efficient at 21.0 BTU/Wh versus 15.2 BTU/Wh for the Airquest PHB524000K000B*. The Airquest PHB524000K000B* is larger at 22200 BTU/hr versus 22000 BTU/hr. Airquest PHB524000K000B* uses a lower-impact refrigerant: R-454B (GWP 470) versus R-32 (GWP 675). Overall, the AUX ASW-H24F4D2/**R3DI-C6 sits higher in the category, ranking above 39% of certified air-source heat pumps.

Efficiency

SpecAirquestAUX
SEER2 (best combination)(BTU/Wh)15.221
SEER2 (worst combination)(BTU/Wh)15.221
HSPF2 (best combination)(BTU/Wh)7.210
HSPF2 (worst combination)(BTU/Wh)7.210
EER2 (best combination)(BTU/Wh)11.513
COP at 5 °F1.602.27

Capacity

SpecAirquestAUX
Cooling Capacity (max)(BTU/hr)2220022000
Cooling Capacity (min)(BTU/hr)2220022000
Heating at 47 °F(BTU/hr)2340023000
Heating at 17 °F(BTU/hr)1200020000
Heating at 5 °F(BTU/hr)84005600

Configuration

SpecAirquestAUX
Product TypeHP - Single PackageHP - Mini or Multi Split
Compressor StagingTwo-stageContinuously variable
Cold Climate CertifiedNoNo
Connected CapabilityNoNo
SeriesQuiet Comfort HPQ-H-series
Indoor-Unit Combinations Rated11

Refrigerant

SpecAirquestAUX
TypeR-454BR-32
GWP RatingR-454B (GWP:470 | Lower GWP)R-32 (GWP:675 | Lower GWP)

More comparisons