SpecDirectory

Airquest PHB524000K000B*vsDeye DWLC2-24KR2(US)

Side-by-side heat pump comparison

Airquest PHB524000K000B*

SEER2

15.2BTU/Wh

HSPF2

7.2BTU/Wh

Cooling Capacity

22200BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

Deye DWLC2-24KR2(US)

SEER2

21BTU/Wh

HSPF2

11BTU/Wh

Cooling Capacity

22000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Deye DWLC2-24KR2(US) is 28% more efficient at 21.0 BTU/Wh versus 15.2 BTU/Wh for the Airquest PHB524000K000B*. The Airquest PHB524000K000B* is larger at 22200 BTU/hr versus 22000 BTU/hr. Airquest PHB524000K000B* uses a lower-impact refrigerant: R-454B (GWP 470) versus R-32 (GWP 675). Overall, the Deye DWLC2-24KR2(US) sits higher in the category, ranking above 39% of certified air-source heat pumps.

Efficiency

SpecAirquestDeye
SEER2 (best combination)(BTU/Wh)15.221
SEER2 (worst combination)(BTU/Wh)15.221
HSPF2 (best combination)(BTU/Wh)7.211
HSPF2 (worst combination)(BTU/Wh)7.211
EER2 (best combination)(BTU/Wh)11.512.5
COP at 5 °F1.602.05

Capacity

SpecAirquestDeye
Cooling Capacity (max)(BTU/hr)2220022000
Cooling Capacity (min)(BTU/hr)2220022000
Heating at 47 °F(BTU/hr)2340027000
Heating at 17 °F(BTU/hr)1200022400
Heating at 5 °F(BTU/hr)840022000

Configuration

SpecAirquestDeye
Product TypeHP - Single PackageHP - Mini or Multi Split
Compressor StagingTwo-stageContinuously variable
Cold Climate CertifiedNoYes
Connected CapabilityNoNo
SeriesQuiet Comfort HPEVI HEAT
Indoor-Unit Combinations Rated11

Refrigerant

SpecAirquestDeye
TypeR-454BR-32
GWP RatingR-454B (GWP:470 | Lower GWP)R-32 (GWP:675 | Lower GWP)